3.3.4.  SMBus Host-to-Battery MessageProtocol 

 

The Bus Host communicates with the battery pack using one of three 
protocols: 

• 

Write Word 

• 

Read Word 

• 

Read Block 

 
3.3.4.1.Write Word  

 
 

The first byte of a Write Word access is the command code. The next 
two  Bytes  are  the  data  to  be  written.  In  this  example  the  master 
asserts the slave device address followed by the write bit. The device 
acknowledges and the master delivers the command code. The slave 
again acknowledges before the master sends the data word (low byte 
first).  The  slave  acknowledges  each  byte  according  to  the  I²C 
specification,  and  the  entire  transaction  is  finished  with  a  stop 
condition. 
 

Write Word Protocol 

 

Write Word Protocol w/PEC 

 

 

SMBus Host (Master)                    Smart Battery (Slave) 

 
3.3.4.2 .Read Word  
 
Reading data is slightly more complex than writing data. First the 
host must write a command to the slave device. Then it must follow 
that command with a repeated start condition to denote a read from 
that device's address. The slave then returns two bytes of data. 
Note that there is not a stop condition before the repeated start 
condition, and that a "Not Acknowledge" signifies the end of the read 
transfer. 
 

Read Word Protocol 

 
 

 

 

Battery 

Address 

Wr  A 

Command 

Code 

Data 

Byte 

Low 

Data 

Byte 

High 

1  1 

1  1 

1  1  8 

1  8 

Battery 

Address 

Wr  A 

Command   

Code 

A  S 

Battery 

Address 

Rd   A 

Data 

Byte 

Low 

Data 

Byte 
High 

A  PEC  !A 

1  1 

1  1 

1  1 

Battery 

Address 

Wr  A 

Command 

Code 

A  S 

Battery 

Address 

Rd 

Data 

Byte 

Low 

Data 

Byte 
High 

!A 

Summary of Contents for SE-2015

Page 1: ...ery Model SE 2015 SE20150NR29 10 8V 5 7AH 61 56Wh Statement of Confidentiality The information contained within this document is confidential and proprietary to Sealed Energy Systems This information...

Page 2: ...ic Levels 12 3 3 3 SMBus Data Protocols 12 3 3 4 SMBus Host to Battery Message Protocol 13 3 3 5 SMBus Battery to Charger Message Protocol 14 3 3 6 SMBus Battery Critical Message Protocol 15 3 3 7 Hos...

Page 3: ...Ah giving a battery pack of 10 8V and 5 7Ah typical The battery is capable of communicating with host or the charger through the System Management Bus SMBus The battery is fully SMBus and SBDS Revisio...

Page 4: ...ffected area with copious amounts of water and seek medical advice Keep batteries clean and dry Secondary batteries need to be charged before use When possible remove the battery from the equipment wh...

Page 5: ...with local state and federal laws and regulations Consult universal hazardous waste regulations for further information regarding disposal of spent batteries If the internal cells are leaking broken...

Page 6: ...Transport Regulations Expended Lithium Ion Battery packs are not considered hazardous waste Lithium ion battery packs that have been involved in a fire maybe considered hazardous waste and should be...

Page 7: ...80 RH The battery shall be capable of continuous discharge within the Operating Boundary as shown in the graph below Host devices should be designed for a controlled shutdown following battery notifi...

Page 8: ...shown in the graph below A dedicated level II or level III smart battery charger is required to charge the battery Using this type of charger the battery will request appropriate charging Voltage and...

Page 9: ...nt on each pack for mechanical alignment adjacent to the positive terminal The SMBus Clock and data lines require separate pull ups to system logic voltage NOT the battery voltage Typically a 10K pull...

Page 10: ...n pack LED s with push button activation Charge control is used to provide optimal and safe charging requests to an SMBus level II or level III charger The system has three modes of operation normal s...

Page 11: ...e not taken into consideration 3 2 3 2 Temperature The internal pack temperature is measured by an NTC thermistor attached to the cell stack Temperature readings have a resolution of 0 1 K The absolut...

Page 12: ...ery Data Specification Rev1 1 Dec15 1998 Smart battery Charger Specification Rev1 0 June27 1996 3 3 2 SMBus Logic Levels SYMBOLS PARAMETERS LIMITS UNITS MIN MAX Vil Data Clock input low voltage 0 3 0...

Page 13: ...te Word Protocol Write Word Protocol w PEC SMBus Host Master Smart Battery Slave 3 3 4 2 Read Word Reading data is slightly more complex than writing data First the host must write a command to the sl...

Page 14: ...t Battery Slave 3 3 5 SMBus battery to Charger Message Protocol The Smart Battery acting as an SMBus master will dynamically alter the charger characteristics of the Smart Charger behaving as an SMBus...

Page 15: ...of the message and that the following 16 bits are its status Battery Critical Message Battery Critical Message w PEC SMBus Host Master Smart Battery Slave 3 3 7 Host to battery Message Slave Mode The...

Page 16: ...ack s internal temperature 0 1 oK r Function Command Code Description Unit Access Default POR Voltage 0x09 Returns the battery s voltage measured at the cell stack mV r Current 0x0a Returns the curren...

Page 17: ...0 Returns a character array containing the manufacture s name string r SES Device Name 0x21 Returns a character array that contains the battery s name string r SE 2015 Device Chemistry 0x22 Returns a...

Page 18: ...threshold OTC recovery 56 C OTD recovery 65OC Bit Battery Status Set When Action When Set Cleared When 11 TERMINATE_DI SCHARGE_ALA RM Relative State of Charge 0 Cell Under Voltage CUV Over Current Dis...

Page 19: ...the secondary are non resettable 3 4 2 Charge Protection Over Voltage The primary protection circuit will prevent the battery from charging if any cell voltage 4300mV Then once all cell voltages are...

Page 20: ...settable rendering the battery pack non functional Over Current The primary protection circuit also provides continuous over current protection and will prevent the battery from discharging at Curren...

Page 21: ...ing Connector The recommended interconnection mating male connector is AMP TE part no 6123738 7 3 6 3 Packing The batteries are packaged in bulk per current regulations 3 7 Environmental Safety Specif...

Page 22: ...0 charge discharge cycles where the charge phase is CC CV C 3 12 6 0 05V and the discharge is C 3 down to 3 0V Cell at 25 C 3 8 2 Warranty Sealed Energy Systems maintains a high quality standard All p...

Page 23: ...rder to prevent parasitic drain on the battery the electronics will go into a shutdown mode if any cell voltage 2300mV If this should happen the battery pack will require an initial low charge to acti...

Page 24: ...SEALED ENERGY SYSTEMS 24 User Manual 4 0 Mechanical Drawing...

Reviews: