SES SE-2015 User Manual Download Page 12

 

 
 

SEALED ENERGY SYSTEMS

®

 

12 

User Manual  

      

 
 

RSOC 

LED1 

LED2 

LED3 

LED4 

LED5 

NOTE 

At below 10% 

 

 

 

 

 

Blinks 

11%-20% 

 

 

 

 

 

Lit for 4 

sec 
when- 
ever 
switch is 
pressed 

21%-40% 

 

 

 

 

 

41%-60% 

 

 

 

 

 

61%-80% 

 

 

 

 

 

81%-100% 

 

 

 

 

 

 
 

3.3. 

SMBus and SBD Parameters   

 

3.3.1.  Overview of Operations 

The battery is fitted with a microprocessor and associated circuitry for 
communication  with  an  external  host  device  and/or  smart  battery 
charger.  Reference  should  be  made  to  the  following  specifications 
when reading this section: 
 

 

System Management Bus Specification (Rev1.1, Dec11, 1998) with 
the exception that it is necessary to wait at least 150uS between 
battery message transactions. 

 

Smart Battery Data Specification (Rev1.1, Dec15, 1998) 

 

Smart battery Charger Specification (Rev1.0, June27, 1996) 
 

  

3.3.2.  SMBus Logic Levels  

 
 
 

SYMBOLS 

PARAMETERS 

LIMITS 

UNITS 

 

 

MIN  MAX   

V

il

 

Data/Clock input low voltage 

-0.3 

0.8 

V

ib

 

Data/Clock input high voltage  

2.1 

5.5 

V

ol

 

Data/Clock output low voltage 

 

0.4 

 
 

3.3.3.  SMBus Data Protocols  

 

SMBus Interface complies with SBS Specification Version 1.1. 
The  battery  pack  includes  a  simple  bi-directional  serial  data 
interface. A host processor uses the interface to access various 
battery pack registers. 

 

The  interface  uses  a  command-based  protocol,  where  the 
host  processor  sends  the  battery  address  command  byte  to 
the  battery  pack.  The  command  directs  the  battery  pack  to 
either  store  the  next  data  received  to  a  register  specified 
command byte or output the data specified by the command 
byte. 

 
 
 

Summary of Contents for SE-2015

Page 1: ...ery Model SE 2015 SE20150NR29 10 8V 5 7AH 61 56Wh Statement of Confidentiality The information contained within this document is confidential and proprietary to Sealed Energy Systems This information...

Page 2: ...ic Levels 12 3 3 3 SMBus Data Protocols 12 3 3 4 SMBus Host to Battery Message Protocol 13 3 3 5 SMBus Battery to Charger Message Protocol 14 3 3 6 SMBus Battery Critical Message Protocol 15 3 3 7 Hos...

Page 3: ...Ah giving a battery pack of 10 8V and 5 7Ah typical The battery is capable of communicating with host or the charger through the System Management Bus SMBus The battery is fully SMBus and SBDS Revisio...

Page 4: ...ffected area with copious amounts of water and seek medical advice Keep batteries clean and dry Secondary batteries need to be charged before use When possible remove the battery from the equipment wh...

Page 5: ...with local state and federal laws and regulations Consult universal hazardous waste regulations for further information regarding disposal of spent batteries If the internal cells are leaking broken...

Page 6: ...Transport Regulations Expended Lithium Ion Battery packs are not considered hazardous waste Lithium ion battery packs that have been involved in a fire maybe considered hazardous waste and should be...

Page 7: ...80 RH The battery shall be capable of continuous discharge within the Operating Boundary as shown in the graph below Host devices should be designed for a controlled shutdown following battery notifi...

Page 8: ...shown in the graph below A dedicated level II or level III smart battery charger is required to charge the battery Using this type of charger the battery will request appropriate charging Voltage and...

Page 9: ...nt on each pack for mechanical alignment adjacent to the positive terminal The SMBus Clock and data lines require separate pull ups to system logic voltage NOT the battery voltage Typically a 10K pull...

Page 10: ...n pack LED s with push button activation Charge control is used to provide optimal and safe charging requests to an SMBus level II or level III charger The system has three modes of operation normal s...

Page 11: ...e not taken into consideration 3 2 3 2 Temperature The internal pack temperature is measured by an NTC thermistor attached to the cell stack Temperature readings have a resolution of 0 1 K The absolut...

Page 12: ...ery Data Specification Rev1 1 Dec15 1998 Smart battery Charger Specification Rev1 0 June27 1996 3 3 2 SMBus Logic Levels SYMBOLS PARAMETERS LIMITS UNITS MIN MAX Vil Data Clock input low voltage 0 3 0...

Page 13: ...te Word Protocol Write Word Protocol w PEC SMBus Host Master Smart Battery Slave 3 3 4 2 Read Word Reading data is slightly more complex than writing data First the host must write a command to the sl...

Page 14: ...t Battery Slave 3 3 5 SMBus battery to Charger Message Protocol The Smart Battery acting as an SMBus master will dynamically alter the charger characteristics of the Smart Charger behaving as an SMBus...

Page 15: ...of the message and that the following 16 bits are its status Battery Critical Message Battery Critical Message w PEC SMBus Host Master Smart Battery Slave 3 3 7 Host to battery Message Slave Mode The...

Page 16: ...ack s internal temperature 0 1 oK r Function Command Code Description Unit Access Default POR Voltage 0x09 Returns the battery s voltage measured at the cell stack mV r Current 0x0a Returns the curren...

Page 17: ...0 Returns a character array containing the manufacture s name string r SES Device Name 0x21 Returns a character array that contains the battery s name string r SE 2015 Device Chemistry 0x22 Returns a...

Page 18: ...threshold OTC recovery 56 C OTD recovery 65OC Bit Battery Status Set When Action When Set Cleared When 11 TERMINATE_DI SCHARGE_ALA RM Relative State of Charge 0 Cell Under Voltage CUV Over Current Dis...

Page 19: ...the secondary are non resettable 3 4 2 Charge Protection Over Voltage The primary protection circuit will prevent the battery from charging if any cell voltage 4300mV Then once all cell voltages are...

Page 20: ...settable rendering the battery pack non functional Over Current The primary protection circuit also provides continuous over current protection and will prevent the battery from discharging at Curren...

Page 21: ...ing Connector The recommended interconnection mating male connector is AMP TE part no 6123738 7 3 6 3 Packing The batteries are packaged in bulk per current regulations 3 7 Environmental Safety Specif...

Page 22: ...0 charge discharge cycles where the charge phase is CC CV C 3 12 6 0 05V and the discharge is C 3 down to 3 0V Cell at 25 C 3 8 2 Warranty Sealed Energy Systems maintains a high quality standard All p...

Page 23: ...rder to prevent parasitic drain on the battery the electronics will go into a shutdown mode if any cell voltage 2300mV If this should happen the battery pack will require an initial low charge to acti...

Page 24: ...SEALED ENERGY SYSTEMS 24 User Manual 4 0 Mechanical Drawing...