background image

 

 
SPECIFICATIONS 

Model 

HVE3000 High Volume Extractor  

Weight 

132 lbs. | 60 kg 

Dimensions 

 

(H × W × D) 

40.2 × 22.5 × 24.8 23.6 in. 
102.1 × 57.2 × 59.9 cm 

Power (115V) 

12A (Blower 1 + Pumpout);  
13.5A (+ Blower 2) 

Tank capacity 

12 gal. | 45 l 

Safety 

Certified to CSA Std C22.2 No. 243 
Conforms to UL Std 1017 

Maximum performance ratings: 

Blower 1 (low blower) 

8 in. Hg (108 in. H

2

O) 

Blower 2 (high blower) 

10 in. Hg (136 in. H

2

O) 

Both blowers 

12 in. Hg (164 in. H

2

O) 

Pumpout discharge rate (1½ in. 
outlet) 

50 gpm  

Pumpout discharge rate (¾ in. 
outlet) 

12 gpm  

Specifications are subject to change without notice. Some values 
may be approximate.  

 

FOR PARTS AND SERVICE CONTACT SERVPRO 
RMA DEPARTMENT.

 

 

 

 

 

SP004 HVE3000 

10 

Dri-Eaz Products, Inc.  

Summary of Contents for 633-115V

Page 1: ...RE HAZARD Keep away from open flames and heat sources Do not use or store where vapors from gasoline solvents thinners or other flammable materials may be present WARNING Unplug unit before cleaning o...

Page 2: ...pairs The SERVPRO RMA Department is here to serve you INTRODUCTION Some assembly required See Before first use p 3 The HVE3000 is a portable flood pumper intended for commercial use It can be teamed w...

Page 3: ...d cause injury Always attach a drain hose and place the end in a suitable drain before activating automatic pumpout system A Power cord socket Provides power to sump pump and blower 1 B Power cord soc...

Page 4: ...t outlet capped when not in use EXTRACTION OPERATION TIP Place the HVE3000 as close as possible to the end of the hose run nearest the wand or other extraction tool This position will maximize the vac...

Page 5: ...blowers emit a high pitched whine and there is no vacuum generated it most likely means that the ball float has engaged and that the tank is full and needs to be emptied or that excessive foam is pre...

Page 6: ...ing maintenance based on hours of use In excessively dusty or dirty conditions it may be necessary to perform these tasks more frequently Blower Motor Replacement 1000 hrs Order the motor brush replac...

Page 7: ...ing the assembly and cleaning it every time you inspect and clean the pump If you are servicing the float ball assembly use a Philips screwdriver to remove the float ball housing retaining screw and r...

Page 8: ...Check float and float shaft and float switch arm for smooth operation Clean as necessary Fold up the pump handle and lift out the pump for inspection Rest the pump on a table or other stable surface p...

Page 9: ...ower cord back through cord grip and retighten cord grip The cord should be slack but should not hang down and interfere with the operation of the float or the float arm assembly Reinstall the float b...

Page 10: ...22 2 No 243 Conforms to UL Std 1017 Maximum performance ratings Blower 1 low blower 8 in Hg 108 in H2O Blower 2 high blower 10 in Hg 136 in H2O Both blowers 12 in Hg 164 in H2O Pumpout discharge rate...

Reviews: