background image

CAUTI ON:  DO NOT OPERATE MACHI NE UNTI L YOU HAVE READ

ALL SECTI ONS OF THI S I NSTRUCTI ON MANUAL

I MPROPER USE OF THE MACHI NE WI LL VOI D THE WARRANTY

1

. Always use a defoamer when foaming occurs to prevent vacuum motor damage.

2

.  Before each use, remove the spray tool from the hose, and check to make sure the spray

nozzles are securely tightened to the spray tool. A loose nozzle could fly off during use.

3

. Keep machine from rain and snow, extremes in temperatures, and store in a heated

location.  Use the machine indoors.  Do not use outdoors.

4

. Never allow the spray to remain fixed in one spot.

5

. Use approved chemicals only.  NO SOLVENTS.

6

. Wear gloves or use rags when removing quick disconnects to prevent burns.

7

. Never use water above 130º  F/ 54º  C in the solution tank.

https://harrissupplyind.com - To Order Parts Call 608-268-8080

Summary of Contents for KC-1200

Page 1: ... The ServiceMaster Company 860 Ridge Lake Blvd Memphis TN 38120 800 756 5656 Tech Support Date 07 31 09 Revision E ServiceMaster Manual Copyright 2004 by ServiceMaster Clean All rights reserved h t t p s h a r r i s s u p p l y i n d c o m T o O r d e r P a r t s C a l l 6 0 8 2 6 8 8 0 8 0 ...

Page 2: ...urely tightened to the spray tool A loose nozzle could fly off during use 3 Keep machine from rain and snow extremes in temperatures and store in a heated location Use the machine indoors Do not use outdoors 4 Never allow the spray to remain fixed in one spot 5 Use approved chemicals only NO SOLVENTS 6 Wear gloves or use rags when removing quick disconnects to prevent burns 7 Never use water above...

Page 3: ...rotect the cord Do not use the cord as a handle close a door on the cord or pull the cord around sharp edges or corners Do not run the machine over the cord Keep the cord away from heated surfaces To unplug grasp the plug not the cord Do not handle the plug the cord or the machine with wet hands Extension cords must be 12 3 and no longer than 50 feet Replace the cord or unplug immediately if the g...

Page 4: ...al or chemical build up that may have formed The vacuum motor pump motors and the pumps do not require any scheduled maintenance however the motors may require replacement brushes after 1000 1500 hours and the high pressure pump and unloader valve may require rebuild kits after 500 1000 hours refer to machine part list for numbers Clean the body with an all purpose detergent and protect it with an...

Page 5: ...k Disconnect KNOW YOUR MACHI NE Recovery Tank Dump Hose Castor Auto Dump Pump Power Cord Recepticle Power Prime Pedal Recovery Tank Wand Holder Wheel Vacuum Hose Connection Recovery Tank Auto fill Hose Connector Wand Holder h t t p s h a r r i s s u p p l y i n d c o m T o O r d e r P a r t s C a l l 6 0 8 2 6 8 8 0 8 0 ...

Page 6: ...elector switch 2 to heat if you want to clean with hot water 5 This switch turns on the automatic pump out OPERATI ON LOW PRESSURE 1 Before each use inspect the machine hoses and cleaning tools for cleanliness and completeness Make sure hoses are in good condition and the spray nozzle s is tight REFER TO THE AUTO FI LL AND AUTO DUMP I NSTRUCTI ONS ON THE FOLLOWI NG PAGES 2 If you choose to use the...

Page 7: ...0 Begin cleaning It may take several cycles to heat the lines and the cleaning tool 1 1 If you are not using the autofill and autodump features turn off the pump and vacuum when the solution tank gets low fill the solution tank and empty and clean the recovery tank 1 2 When finished with the job turn off the water source Vacuum the remaining solution from the holding tank into the recovery tank Ru...

Page 8: ... 8 Prime the 1200 psi pump using the power prime system turn on both the pump and the vacuum cover the hole in the hose barb with your hand then depress the Power Prime Pedal This will pull trapped air through the pump and into the recovery tank priming the pump You will notice a tone change from the pump smoother with less of a rattle and the water being pulled into the recovery tank will change ...

Page 9: ...switch switch is locat ed on the switch panel on the top of the machine NOTE the dump pump is self priming You should see water start to flow within 30 seconds of the pump turning on If water does not begin to flow check the filter to see if it is plugged with debris After each job run clear water though the dump pump to wash out any chemical residue Remove and clean the stainless steel filter in ...

Page 10: ...h t t p s h a r r i s s u p p l y i n d c o m T o O r d e r P a r t s C a l l 6 0 8 2 6 8 8 0 8 0 ...

Page 11: ...ng 3 8 x 1 4 pipe 148 148 Elbow 90º 149 239 Adapter brass3 4hose 1 1303 Switch Plate 2 78 Light green 120V 3 78B Light red 120V 3A 227 Light green 230V 4 56220001 Switch selector ON OFF ON 5 FP345 Switch ON OFF with actuator 6 FP364 Ball float manifold assembly 7 929B Ballfloat 10 805 Chain lidretaining 11 1074 Gasket recovery lid 12 2086A Lid and ring 6 14 937 Bushing PCV 15 2069B Filter Auto dum...

Page 12: ...e ServiceMaster Company 860 Ridge Lake Blvd Memphis TN 38120 800 756 5656 Tech Support Date 1 26 09 NOTES h t t p s h a r r i s s u p p l y i n d c o m T o O r d e r P a r t s C a l l 6 0 8 2 6 8 8 0 8 0 ...

Reviews: