Seresco CLASSIC NE Series Operation And Maintenance Manual Download Page 30

W – Warranty 

OMM.W.S.ZZ.02

 

W-

1

 

March

 2019

 

Warranty 

General Policy 

This warranty applies to the original equipment owner and is not transferable. Seresco Technologies Inc. warrants 
as set forth and for the time periods shown below that it will furnish, through a Seresco Technologies Inc. 
authorized installing contractor or service organization, a new or rebuilt part for a factory installed part which has 
failed because of defect in workmanship or material. 

Warranty Void Unless Registered 

Warranty is void unless, upon start-up of the equipment, the “Warranty Registration and Start-up Report” is 
completed and sent to the factory within one week of initial start-up. This report will also register the compressor 
warranty with the compressor manufacturer. 

Initial 90-day Warranty 

During the first 90 days from initial start-up and prior to the completion of the 24

th

 month from date of shipment, 

whichever comes first and subject to prior written approval from the factory, Seresco Technologies Inc. will 
provide and/or reimburse the required labour, materials, and shipping and handling costs incurred in the 
replacement or repair of a factory installed defective part. Only the labour required to replace the defective part is 
warrantied – travel time, diagnostic time, per diems, truck charges, etc. are not covered under this warranty. 

WebSentry Conditional One Year Extended Labour Warranty 

The initial 90-day labour warranty shall be extended for a total of 12 months from initial start-up and prior to the 
completion of the 24

th

 month from date of shipment, whichever comes first and subject to prior written approval 

from the factory. The provided equipment must be connected and communicating to Seresco's WebSentry online 
control and monitoring service for the entire term of the warranty extension. Seresco Technologies Inc. will 
provide and/or reimburse the required labour, materials, and shipping and handling costs incurred in the 
replacement or repair of a factory installed defective part. Only the labour required to replace the defective part is 
under warranty – travel time, diagnostic time, per diems, truck charges, etc. are not covered under this warranty. 

Two Year Parts Warranty 

If any factory installed part supplied by Seresco Technologies Inc. fails because of a defect in workmanship or 
material prior to the completion of the 24

th

 month from date of shipment, Seresco Technologies Inc. will furnish a 

new or rebuilt part F.O.B. factory. No labour reimbursement will be made for expenses incurred in making field 
adjustments or parts replacement outside the 

Initial 90-day Warranty

. Seresco Technologies Inc. reserves the right 

to have the defective part returned to the factory in order to determine the warranty applicability. Parts shipping 
and handling costs (to and from the factory) are not covered outside of the 

Initial 90-day Warranty

Summary of Contents for CLASSIC NE Series

Page 1: ...NE Series Dehumidifiers NE 002 and NE 003 NE 204 and NE 206 CLASSIC Indoor Model Operation and Maintenance Manual Seresco Technologies Inc Serescodehumidifiers com...

Page 2: ...Data C 7 Chapter D Layout and Components D 1 Dehumidifier Main Components D 1 Control System D 2 Outdoor Air Condensers and Fluid Coolers Layout and Components D 4 Chapter E Sequence of Operation E 1...

Page 3: ...B Table of Content B 2 This page is left blank...

Page 4: ...edures Failure to follow safety procedures can result in serious injury or death Beware of moving parts and hot surfaces Make sure to stop all moving parts fans blowers etc before accessing the equipm...

Page 5: ...3603 ext 2 Fax 613 680 5301 Attention Installation and Service Contractors WARNING Any work installation start up service maintenance repair etc on any mechanical equipment dehumidifier outdoor conden...

Page 6: ...d 6 ton cooling capacity appx models NE204 to NE206 Airflow and ductwork connection options Return Supply and Outdoor Air see Pic C 1 Optional Pool Water Heating Optional Space Heating hot water coil...

Page 7: ...ng connection to the fluid cooler or other external water cooled system such as geothermal cooling tower etc Therefore only one of these options present with the actual dehumidifier Gas line If the de...

Page 8: ...efrigeration circuit Single and Two Compressor Arrangement Dehumidifier Model Dehumidifier typical arrangement total capacity and number of compressors are reflected in its model for specific dehumidi...

Page 9: ...bmittal documentation for more details Two compressor dehumidifier would normally have paired up two outdoor condensers of respective size one per compressor The pump package is optional the fluid coo...

Page 10: ...ehumidifier to show External systems connections location direction pool space heating cooling circuits condensate Air filter locations quantity and size Additional Info warning caution stickers etc W...

Page 11: ...C General Information C 8 This page is left blank...

Page 12: ...e same for all dehumidifiers of current type however some may vary based on the dehumidifier s specific options refer to submittal documentation Pic D 1 below shows all most available options some of...

Page 13: ...other components are located within the Compressor Compartment 3 o If the dehumidifier has the standard pool water heating option the compressor circuit includes the coaxial pool water heat exchanger...

Page 14: ...k downstream of the space heater If the dehumidifier is equipped with the pool heating option the Pool Water Temperature sensors Pool In 25 and Pool Out 26 measure the entering and leaving pool water...

Page 15: ...cooler piping connections 33 are identified respectively IN OUT Hot gas Liquid etc In some cases fluid cooler piping connection s may be located within pump package box 37 if fluid cooler is provided...

Page 16: ...ablishes glycol mixture circulation through the fluid cooler and dehumidifier Expansion tank 39 compensates for temperature based glycol volume fluctuation The pump package electrical sub panel 40 con...

Page 17: ...D Layout and Components D 6 This page is left blank...

Page 18: ...table pre set variable signals the exhaust fan speed may vary depending on scheduled ventilation mode Occupied Non Occupied and Spectator or call for Economiser Mode as part of Air Conditioning and or...

Page 19: ...midifiers equipped with pool water heating option also engage the refrigeration pool water heating solenoid valve to reject heat into the pool water based on pool water temperature Once demand for the...

Page 20: ...ter glycol heating circuit that consists of a hot water coil instantaneous gas boiler pump and mixing 3 way valve Boiler package piping general schematic is shown on Pic E 2 depending on required capa...

Page 21: ...E Sequence of Operation E 4 This page is left blank...

Page 22: ...etc Advanced Access to advanced settings and features Help Context sensitive help presenting information related to the viewed page Most common basic maintenance tasks performed using Touch Display O...

Page 23: ...ltage etc is outside of pre set limits Check Voltage Monitor info status incoming power voltage Compressor HP1 X LP1 X SupHeat1 DisTemp1 Various compressor related alarms relevant to Compressor high d...

Page 24: ...rate RJ 45 jack plastic black is mounted on the control board directly for TouchDisplay connection Make sure to use the proper jack metal surface one located on the sub board for Web Monitor connectio...

Page 25: ...F Interface and Communication F 4 This page is left blank...

Page 26: ...erforming any equipment maintenance work make sure that all moving parts are stopped and it is safe to perform required task Maintenance Key Points Here are some basic key maintenance considerations p...

Page 27: ...y Verify that all set points are correctly programmed as specified by the facility operator Semi Annually Inspect and clean the drain pan s Tighten electrical connections if required Check and tighten...

Page 28: ...ils Warning Hazardous chemicals Cleaning agents can be highly acidic or alkaline Handle all chemicals carefully and use appropriate personal protective equipment PPE Refer to the cleaning agent manufa...

Page 29: ...tire system fluid cooler piping dehumidifier etc Have each local high point of the system equipped with means to bleed the air air bleeding valve etc Have each local low point of the system equipped w...

Page 30: ...nty WebSentry Conditional One Year Extended Labour Warranty The initial 90 day labour warranty shall be extended for a total of 12 months from initial start up and prior to the completion of the 24th...

Page 31: ...em not supplied by Seresco Technologies Inc 6 Products on which the model and or serial number plates have been removed or defaced 7 Products which have become defective or damaged as a result of unau...

Page 32: ...tended warranty must be purchased before the shipment of the equipment Seresco Technologies Inc will provide a replacement Airside Coil for 60 months from the date of shipment provided the failed coil...

Page 33: ...ry with transportation prepaid This extended component warranty is subject to all the terms of the standard Seresco Technologies Inc warranty but applied to the driveline components only Driveline Com...

Reviews: