background image

www.SereneLifeHome.com

3

       SAFETY WARNING

For your safety, please read the following contents carefully before 
using this dehumidifier.

Requirements:

 • 

Install this humidifier in smooth place to reduce vibration and noise. 

   Keep a distance of at least 50cm between appliances and surroundings.

 • 

Do not place this dehumidifier in water or other liquids.

 • 

In order to prevent accidents, please do not use this dehumidifier if wires or  

 

   other connections are damaged.

 • 

Users of this appliance must be at least 8 years old. Those who are weak, those

   with poor sensory ability, or those with low mental quality must supervise their
   use with an understanding of the correct use and harm. 
   Children are prohibited from playing. Children need to clean and maintain the    
   appliance under supervision.

 • 

When stop, reset or clean this dehumidifier, please cut off the power.

 • 

Please use at the specified voltage.

 • 

This dehumidifier can only be used indoor, please do not use for other purposes.

 • 

Please do not place heavy objects on this dehumidifier.

 • 

Please empty water tank to prevent overflow and spill before restarting this  

 

   dehumidifier.

 • 

Please do not incline in case that the spilled water damages this dehumidifier.

 • 

Please do not place waste rods and hard objects into the dehumidifier in case

   that error and damage occur.

 • 

If the supply cord is damaged, it must be replaced by the manufacturer, its  

 

   service agent or similarly qualified persons in order to avoid a hazard.

 • 

In the event of an abnormality (such as a burning smell), turn off the machine

   and unplug the power cord.

 • 

The appliance should be installed in accordance with the corresponding national  

   wiring regulations and ensure reliable grounding.

Summary of Contents for SLDEHU30

Page 1: ...Compact Dehumidifier SLDEHU30 SLDEHU50 Electric Dehumidifiers for Quiet Efficient Intelligent Humidity Control on Small Medium Rooms ...

Page 2: ... TABLE OF CONTENTS Safety Warning Frequent Enquiries Installation HEPA Filter Installation Components Control Panel Operation Methods Drainage Maintenance Troubleshooting Features and Technical Specs 3 4 5 5 7 8 9 10 12 13 14 ...

Page 3: ...intain the appliance under supervision When stop reset or clean this dehumidifier please cut off the power Please use at the specified voltage This dehumidifier can only be used indoor please do not use for other purposes Please do not place heavy objects on this dehumidifier Please empty water tank to prevent overflow and spill before restarting this dehumidifier Please do not incline in case tha...

Page 4: ...ced Although only a little water collects in the tank this is not a malfunction Q Why doesn t the dehumidifier operate Why does the unit stop operating suddenly This dehumidifier may be full of water or water tank is not installed properly drain the water in water tank or re install water tank in correct way At the moment the dehumidifier may be in dehumidification mode the ambient temperature is ...

Page 5: ...right is 20cm as required as shown in figure below Theres loud noise during operation Place the unit on top of a mat This reduces vibration and noise It also prevents leaving depressions on carpets 1 HEPA FILTER INSTALLATION The HEPA filter screen is installed in the filter frame to purify the air Remove the rear filter frame Install the equipped HEPA filter into the filter frame Install the filte...

Page 6: ...hidden 88 display filter frame HEPA filter www SereneLifeHome com 6 2 Hidden 88 display The hidden status is synchronized with the top digital display ...

Page 7: ...www SereneLifeHome com 7 COMPONENTS Front Back Handle Power cord storage column Draining Port Filter frame Caster Water tank Water tank handle water tank cover Front panel Rear Panel Control panel ...

Page 8: ... the fan speed HIGH and LOW can be circularly selected 4 LCD Display In AUTO CONTINUOUS AND DRYING modes etc this indicator displays room humidity When it is set in AUTO mode this indicator shows the set humidity and displays the set time in timer state represents percentage of humidity 5 Humidity Setting Once this key is pressed the humidity is displayed circularly in the range of 30 35 40 45 50 ...

Page 9: ... act at all within 5s the set time is confirmed In timer ON state the key lamp on the Timer key is normally on and the set time is displayed on control panel AUTO MODE Select AUTO dehumidification if the room humidity is high than the set humidity or is between 5 or 5 of the set humidity the compressor will starts and the fan will run at the set speed If the room humidity is lower than the set hum...

Page 10: ... on LCD flashes the compressor fan and negative ion will stop running the BUZZER sounds for 10 times to remind the user till water is drained Attention When the water tank is full of water please empty it Before putting the water tank into the dehumidifier please confirm whether the floater rotates flexibly or not and then push it in position with both hands Place both hands respectively at the si...

Page 11: ...e drain outlet at the back unscrew the drain cover and pull out the water plug Connect the 9 0mm drainage pipe to the drain outlet Attention The external water pipe must not be too long the recommended length is less than 0 6 meters The height of the end of the water pipe must be more than 10cm lower than the height of the water outlet The water pipe must be kept smooth otherwise the water may not...

Page 12: ... chemical solvents such as alcohol gasoline and benzene etc Please clean the water tank and its cover with a soft cloth dipped in cold or warm water regularly to prevent mould inside the dehumidifier Wipe the surface of the dehumidifier slightly with wet cloth and do not use detergent or abrasive in case the plastic surface is damaged Clean the filter and the frame at lease once per two weeks simp...

Page 13: ...blocked Clean the air filter net according to the above method Noise is abnormal during operation Is the dehumidifier placed improperly so that it is inclined or unstable Place the dehumidifier in a smooth place Is the air filter net blocked Clean the air filter net according to the above method There is tittering sound The flowing sound of refrigerant which is a normal phenomenon Water leaks Conn...

Page 14: ...With High Efficiency Compressor and Fan 1 24 Hours Auto ON OFF Timer Auto Shutoff when Water Tank Full Continuous Drain Hose Included 3 Prong Plug Adjustable Fan Speed Recessed Handles Adjustable Humidity Auto Error Detection 3 Min Compressor Delay 2 Fan Speed Washable PP Filter Replaceable HEPA filter WHAT S IN THE BOX Compact Dehumidifier HEPA Filter Draining Pipe ...

Page 15: ... High Powered Power Output Moisture Removal 3 1A 6A Up to 1500 sq ft Up to 3000 sq ft up to 30 Pints and 700 Sq ft up to 50 Pints and 1000 Sq ft 260 Watt 420 Watt 30 pints day 17L day new DOE 24 pints day 14 L day 50 pints day 28L day new DOE 35 pints day 20 L day This product can expose you to a chemical or group of chemicals which may include Acrylonitrile which is known in the state of Californ...

Page 16: ...Questions Issues We are here to help Phone 1 718 535 1800 Email support pyleusa com ...

Reviews: