Positioning
This heater is water resistant to IP24. It can therefore be used in
bathrooms or other areas subject to humidity, The heater must be
installed so that switches and other controls cannot be touched by a
person in the bath or shower.
The heater must be mounted on the wall, with a minimum height of 300mm
above the floor or any other objects heated below it, and a minimum
distance of 400mm below the ceiling and from adjacent walls.
The heater must not be located immediately below a socket outlet.
Ensure that the heater is not mounted in a situation where the heated air is
directed over an open door, curtains, or any towel rail, creating a fire risk.
Leave at least 1 metre of space in front of the heater to allow correct air
delivery.
The heater must be mounted a minimum distance of:
300mm above floor level or any other objects heated below it
Wall
Floor
Wall
400mm
Min.
400mm
Min.
300mm
Min.