Positioning

This heater is water resistant to IP24. It can therefore be used in

bathrooms or other areas subject to humidity, The heater must be

installed so that switches and other controls cannot be touched by a

person in the bath or shower.
The heater must be mounted on the wall, with a minimum height of 300mm 

above the floor or any other objects heated below it, and a minimum 

distance of 400mm below the ceiling and from adjacent walls.

The heater must not be located immediately below a socket outlet. 

Ensure that the heater is not mounted in a situation where the heated air is

directed over an open door, curtains, or any towel rail, creating a fire risk.

Leave at least 1 metre of space in front of the heater to allow correct air

delivery.

The heater must be mounted a minimum distance of: 
300mm above floor level or any other objects heated below it 

Wall 

Floor 

Wall 

400mm 

Min. 

400mm 

Min. 

300mm 

Min. 