DA
L
19
65
Pag. 4/6
M
T
/8
0
/2
I
E
!
3-Take the motor out of the metal botton box.
ATTENTION
The motor is fixed on the foundation box by means of two normal nuts, due to problems of
transport. To install the motor in the system, these two nuts have to be removed and trown away,
replaced with four self-locking nuts as standard
4-Arrange the founding box at ground level and check the horizontal level and the perfect vertical alignment of the upper
hinge with the foundation box pin. Check that the distance between the pillar and the centre of the pin is higher than 65
mm.
The lower hinge -if present- must be removed.
5-The lower hinge -if present- must be removed.
6-Pre-arrange piping for the draining of the rainfall.
7-Cement definitively with concrete.
The connection between the power supply cable of the motor and the cable of the control panel
has to be carried out outside the foundation box and inside a weather proof housing. On the
contrary a water infiltration may be occur through the power supply cable causing the motor
failure.
GATE HING
STIRRUP WITH UNCLAMPING
ENTRANCE CABLES
1
2
3
WATER DRAIN PIPE WITH SUITABLE
SLOPE
VERY IMPORTANT
WELL WITH ABUNDANT DRAINAGE FOR
THE WATER DRAIN
WATER-PROOF CONTAINER WHERE TO
CARRY OUT ELECTRIC CONNECTIONS
195
!
THE MINIMUM DISTANCE
BETWEEN PILLAR AND CENTRE
OF THE PIN MUST BE 65 mm
!
DRAIN PIPE