background image

DA

L  

19

65

Pag. 2/10

2

5

0

1

4

4

1

1

0

265

66

180

Z18 M4

4

0

0

2

5

0

265 

1

3

0

9

1

232

14

14

3

0

3

0

1

8

0

DIMENSIONS OF THE MOTOR

Motor MT/18

Motor MT/25 with
inside fan

Electronic control
panel CR/14

Radio receiver
card SOG/4A

Minitransmitter
 OG/62

Flasher with
antenna RZ/07/1F

Electric key
M/10

Pair of
photocells P/94

Pair of limit switch
slide blocks

Release key
Key for clutch adjustment

Base plate PM/13

Elbow support

KIT/18F     KIT/18H       KIT/25H   

X

X

X

X

X

X

X

X

X

X

X

X

X

COMPONENTS OF THE KIT

X

X

X

X

X

X

KI

T/

18

F-

18

H-

25

 I 

E

Summary of Contents for KIT/18F

Page 1: ...CE marking Machines 98 37 EEC Low voltage 73 23 EEC Electromagnetic compatibility 89 336 EEC R TTE Radio and Telecommunications Terminal Equipment 99 5 EEC General applicable standards Electrical saf...

Page 2: ...tronic control panel CR 14 Radio receiver card SOG 4A Minitransmitter OG 62 Flasher with antenna RZ 07 1F Electric key M 10 Pair of photocells P 94 Pair of limit switch slide blocks Release key Key fo...

Page 3: ...en the contacts Or alternatively use a 10Amagnetothermic switch 2 When making the connections using any type of connector ensure the system is disconnected from the power supply i e that the main swit...

Page 4: ...E PLATE PM 13 FOR THE FIXING OF THE GEARED MOTOR Insert the nut C in the 4 holes of the base plate B Screw the tie rod E to the nut C until it stops Picture 2 Screw the nuts Ato the screws F Picture 2...

Page 5: ...top point of the gate after the end run intervention depends a on the weight of the gate b on the sliding speed c on the frictions d on the temperature The a and b features are constant whereas the c...

Page 6: ...s out and give power supply in order to check if the motor power is the appropriate one otherwise repeat the operations Remember that the strong differences in temperature between summer and winter ca...

Page 7: ...neutral WIRING DIAGRAM CR 14 PER 230V THREE PHASE 9 8 M R S T 10 11 STOP NC NC NC NC 24 V MAX 300 mA MOTOR 230 V THREE PHASE see Fig 12 NC R S T N ELECTRIC NETWORK 230V three phase neutral 24 V ELECT...

Page 8: ...s Gate open pause T1 2 s 1 1 reverse direction automatic restart after stopping from photocell drive on closing action ON OFF 2 s automatic restart in the same direction after stopping from photocell...

Page 9: ...itransmitter it is necessary to execute the procedure for the receiver programming 1 keep pressed the button of the chosen channel for 1 sec the led will flash and then it will remain fix ATTENTION do...

Page 10: ...hem Unsuitable gearmotor position Check that the distance between the end stop sliding plate and the front outgoing trim of the spring adjust them The gate does not startor the motor slips Clutch adju...