Model 700 Programmer – Operations Manual
© Sequential Circuits Inc. 1979 PDF Version by the Emulator Archive 2002 Page 7
3.0 Synthesizer Connections
3.1 ARP 2600
Make the following connections with patch cords between the programmer and
the 2600:
PROGRAMMER
2600
GATE
GATE
TRIGGER TRIGGER
EXTERNAL VOLTAGE
KEYBOARD CV OUT
VOLTAGE 1
OSCILLATOR 1
KEYBOARD CV IN
VOLTAGE 2
OSCILLATOR 2
KEYBOARD CV IN
VOLTAGE 3
OSCILLATOR 3
KEYBOARD CV IN
ENVELOPE 1
VCA ADSR CONTROL IN
ENVELOPE 2
VCF ADSR CONTROL IN
Set the VOLTAGE 1, VOLTAGE 2, VOLTAGE 3, and ENVELOPE 2 switches to
the ADD EXT position. Turn VOLTAGE 1, VOLTAGE 2, and VOLTAGE 3
controls fully counter-clockwise, and set the mode to VARIABLE. Tune the three
oscillators to the lowest note that you will need. From now on, do not change the
tuning of the oscillators on the synthesizer; make all changes from the
programmer. Also, do not use the ADSR or AR envelope generators on the
synthesizer; use the envelopes on the programmer. You are now ready to start
setting up your programs and storing them as required.