CHAPTER 4. COMMON RECE
I
VER OPERAT
I
ONS
4.1.2 Output over Ethernet
SBF and NMEA data can be sent over an Ethernet connection from the AsteRx SBi3.
Step 1: Configure an IP connection on the AsteRx SBi3
The Ethernet port settings can be con
fi
gured by selecting
IP Ports
from the
Communication
menu.
I
n the example shown in Figure 4-8, port 600 has been con
fi
gured as connection
I
PS1
in
TCP2Way
mode so data can be received as well as transmitted over the connection. When
choosing a port number, avoid con
fl
icts with other applications such as the commands port
(28784), the webserver port (80), the FTP port (21) as well as the default NTR
I
P port (2101)
and the NTP port (123).
Note that a new
I
P port can also be con
fi
gured by followings the sequence of settings for
NMEA output described in
Step 2
.
Figure 4-8:
Con
fi
guring the TCP/
I
P server port setting for data output
27