CHAPTER 4. COMMON RECE
I
VER OPERAT
I
ONS
Step 3: Verifying the configuration
Having con
fi
gured the data output and clicked on
Ok
, the
NMEA/SBF Out
page will now
display a summary of all data output as shown in Figure 4-6.
Figure 4-6:
Summary of all con
fi
gured data output streams
Figure 4-7 shows the actual data output. NMEA is in ASC
II
and is thus readable unlike SBF
which is formatted in binary.
I
n this example, the serial COM was connected to a PC via a
USB adapter which maps the serial connection to a virtual COM9 of the PC.
Figure 4-7:
Example showing output of NMEA GGA (left panel) and SBF
PVTCartesian (right panel) data
26