21
21
SBG Ellipse2 Micro
21
3.2
Environmental
Operational: -40 to +85 °C
Storage:
-40 to +85 °C
3.3
Power Consumption
The IMU consumes 400mW.
3.4
Connector
The main connector uses a 10 ways Harwin Gecko connector. The exact receptacle
reference is: G125-FS11005L0P. The mating connector is Harwin G125-3041096L4 (plus
contacts).
The input voltage range (VIN pin) is from 4 to 15V.
3.5
Open-Ended Cable
Septentrio’s
CBL_AxiS_OEM_IMU cable (part# 215684) can be used to connect the IMU to
the AsteRx-i S OEM. Twisted pairs are used when applicable to prevent cross-talk between
digital signals. The wiring diagram and the wire colors are indicated below.