background image

REFRENCE DATA 3: 

Setting Value of Vacuum Pressure Degree

14

Temperature (

)

kPa(abs)

Torr

mbar

15

1.7

12.8

17

20

2.3

17.3

23

25

3.2

24

32

30

4.2

31.5

42

14

1.  For Water or Aqueous Liquid

Recommended Degree of Vacuum

5kPa(abs) 

10kPa(abs)

= 50mbar(abs) 

100mbar(abs)

The above pressure is the recommended value when using the module at 15-30

.

When using the module at temperatures lower than 15

or higher than 30

,

please contact DIC for more details. 

The above vacuuming pressure is not suitable for every application. Depending on

applications, composition, and target degassing performance, the most suitable
vacuuming value may be different from the above value. 

Reference

Saturated Water Vapor Pressure

2.

For Non-Aqueous Liquid.

Recommended Vacuuming Degree: We recommend setting weaker degrees (higher 

in

value) than the recommended saturated vapor pressure of the liquid.

Ex

In cases where saturated vapor pressure is 8kPa(abs), we recommend a weaker vacuum

degree than 10kPa(abs).

As the vacuum pressure degree approaches a perfect vacuum, degassing
performance is improved. However, if the vacuum pressure degree is too strong
yet close to perfect pressure, liquid may evaporate and penetrate through the
membrane. As a result, the composition of liquids may change. Therefore, DIC
recommends following the exact vacuum pressure degree.

Application Materials Product Division

INSTRUCTION MANUAL

Summary of Contents for EF-G2 Series

Page 1: ...and proper use DIC will not have any liability to a customer or end user in connection with any costs and damages arising directly or indirectly from any defective modules We are not responsible for any usage installation or any other handling done by the customer The module must be used installed and handled responsibly by the customer For IJ Hollow Fiber Membrane Module Ver 1 5 June 3 2016 Appli...

Page 2: ...ge methods storage methods and risks associated with the product module within this manual Please note that this manual does not describe all information about risks related to usage and storage of the product Although the content of this instruction manual is based on reliable testing and measurement results no guarantees are provided for its accuracy DIC does not have any responsibility for anyt...

Page 3: ...id Maximum 12 months from the date of delivery of the module 1 Non Water Based Liquid Maximum 6 months from the date of delivery of the module 1 1 The warranty periods shown above are strictly to demonstrate the maximum warranty period available for the modules Any actual warranty period will be based upon the results of compatibility tests of the module with all liquids which may come in contact ...

Page 4: ...nt This is the sole remedy available to the customer under this warranty DIC will not have any liability to a customer or end user in connection with any costs and damages arising directly or indirectly from any defective modules We are not responsible for any usage installation or any other handling done by the customer The module must be used installed and handled responsibly by the customer The...

Page 5: ...10 6 Restart P 11 7 Maintenance P 11 Reference Data 1 Basic Principles of Degassing P 11 2 Vacuum Pressure Degree P 12 3 Setting Value of Vacuum Pressure Degree P 13 4 Range of Liquid Flow Rate P 14 5 Inner Volume P 15 6 Trouble shooting P 16 Contacts P 17 5 Application Materials Product Division INSTRUCTION MANUAL ...

Page 6: ...organic solvents alcohol oils or any other liquid which is not compatible with the liquid and materials that SEPAREL modules are composed of 1 5 Do not remove the end cap of SEPAREL modules In cases where liquid that has not been deemed compatible by DIC is used no warranty will apply to the product 2 1 Check the label and shape of the module to confirm that the type and series number are the same...

Page 7: ...ply too much pressure to the connection Do not shake or shock the SEPAREL module Shaking or shocking SEPAREL may damage the module even if it is a light impact Because the housing of the SEPAREL module is composed of PP polypropylene excess pressure to the connector may cause damage to the connecting port Excess pressure to connecting port may shave thread and cause resin particles to appear in th...

Page 8: ...le Optimal flow direction differs by use conditions and the above flow direction is not always the correct direction For suitable flow direction contact us Liquid Feeding Pump Liquid Tank Filter Vacuum Pump Leak Valve Trap Vacuum Meter Degassing Module Filter 3 INSTALLATION Application Materials Product Division INSTRUCTION MANUAL ...

Page 9: ...the maximum operating pressure If you use a solenoid valve select one which dose not cause sudden opening shutting If you use two modules in parallel properly measure the liquid flow into both modules and ensure that liquid flow is equal If impurities and large particles remain in liquid install a filter in front of the SEPAREL module Use RO water or higher quality water for the water supply In th...

Page 10: ... 4 Do not change the flow rate dramatically in order to ensure that the hollow fibers are not damaged by drastic pressure fluctuations 4 5 If vacuum pressure is very strong and conditions are close to a perfect vacuum situation stop the vacuum pump when liquid flow has stopped Strong vacuuming for an extended period of time without liquid flow may freeze and damage hollow fibers via vaporization h...

Page 11: ...off period is extensive remove the SEPAREL modules and store after cleaning and drying completely If it is difficult to uninstall the SEPAREL module fill it with liquid that is compatible with SEPAREL and close all liquid and vacuum ports completely Even liquid that is compatible with degassing module materials can lead to bacteria generation if it is left in the module during shutoff periods The ...

Page 12: ...gas 12 Vacuuming Liquid Image of Hollow Fiber Cross section Hollow Fiber Membrane Hollow Fiber Membrane Inside of Hollow Fiber for Vacuuming Hollow Fibers By vacuuming inside the hollow fiber only gas can pass through hollow fiber membrane and is removed from liquid Application Materials Product Division INSTRUCTION MANUAL ...

Page 13: ...ar 494 Torr Recommended range of vacuum pressure degree Refer to Reference Data 3 13 Absolute Pressure For vacuuming conditions every value should be 0 or plus It cannot be minus Gauge Pressure For vacuuming conditions every value should be 0 or minus It cannot be plus Reference Absolute pressure Gauge pressure 1atm The value for maximum pressure resistance is indicated by gauge pressure Note that...

Page 14: ...suitable vacuuming value may be different from the above value Reference Saturated Water Vapor Pressure 2 For Non Aqueous Liquid Recommended Vacuuming Degree We recommend setting weaker degrees higher in value than the recommended saturated vapor pressure of the liquid Ex In cases where saturated vapor pressure is 8kPa abs we recommend a weaker vacuum degree than 10kPa abs As the vacuum pressure d...

Page 15: ...momentarily the hollow fiber may be damaged and ink may leak into the vacuum line The warranty will not apply in cases where liquid feeding pressure exceeds the maximum pressure value specified in the specification sheet Even if liquid feeding pressure is lower than the specified maximum pressure an increased flow rate will cause lesser degassing performance On the other hand if the flow rate is t...

Page 16: ... EF MICRO Approx 4 ml EF G2 Series Approx 11 ml EF G3 Series Approx 40 ml EF G5 Series Approx 85 ml The above values are for reference and are not guaranteed values Actual volume may differ by connection type 16 Application Materials Product Division INSTRUCTION MANUAL ...

Page 17: ...RENCE DATA 6 Image of Connecting Port EF G2 Series Liquid IN OUT Liquid IN OUT Vacuum Port EF G3 Series Vacuum Port Liquid IN OUT 17 EF G5 Series Vacuum Port Liquid IN OUT Liquid IN OUT Liquid IN OUT INSTRUCTION MANUAL Application Materials Product Division ...

Page 18: ...ghai Co Ltd Address 12th Fl Metro Plaza No 555 Lou Shan Guan Road Shanghai 200051 People s Republic of China TEL 86 21 6228 9911 FAX 86 21 6241 9269 Korea DIC Korea Corporation Address 3rd Fl The Korea Chamber of Commerce Industry 39 Sejong Daero Jung Gu Seoul 100 743 Republic of Korea TEL 82 2 317 6200 FAX 82 2 752 1059 Oceania Asia except for Japan China and Korea DIC Asia Pacific Pte Ltd Addres...

Reviews: