Installation Guide for the SolaStat™-Plus-ET
Version 1.2 – July 2011
Page 28
S
OLA
S
TAT
TM
-P
LUS
-ET
S
PECIFICATIONS
Power Supply.
Supply Voltage.
-H
85~264Vac/dc (Standard model)
-M
22~85Vdc. (Must be specified at time of ordering.)
-L
10~28Vac/dc. (Must be specified at time of ordering.)
Max power usage.
5VA + external loads.
Relay Outputs
Three options are available (All ratings at 240Vac)
Supply Voltage.
-1
1.1hp motor
10A
resistive
flexible
wiring
-2
2x1hp motor. 1hp combined load
10A resistive combined load flexible wiring
Sensors.
Display range
-20 ~ +140ºC
Control Range
-40 ~ +150ºC
Stainless steel tip
-40 ~ +150ºC; 6mm diameter x 30mm
PVC Sensor cable
-40 ~ +105ºC; 4mm diameter, UV resistant. (Standard Models)
Silicon Sensor cable
-40 ~ +150ºC; 4mm diameter, UV resistant. (Special Order)
Accuracy
+/-1C @ 25ºC
Installer Adjustable Values Range
(Adjustable in Installer Programming Mode)
Pump On
2
21
º
C (Roof –Inlet Sensor)
Pump
Off
1
20
º
C (Roof – Inlet Sensor)
Energy Transfer Off in Summer
1
70
º
C
Energy Transfer On in Summer
2
90
º
C
Energy Transfer Off in Winter
1
70
º
C
Energy Transfer On in Winter
2
90
º
C
Frost Protection
1
10
º
C with +2
º
C hysteresis or OFF
Topout
1
120
º
C with +2
º
C hysteresis or OFF
EMC and Safety Compliances.
Emissions:
EN
55022-A,
CTick.
Immunity:
EN
50082-1.
Safety Compliance:
EN 60950, CTick.
General Specifications
.
(Unless otherwise stated in other input specifications.)
Operating Temperature:
0~60C
Operating Humidity:
90% RH Max. Non-Condensing
Enclosure Construction
Polycarbonate - Impact Resistant
UL94 V-2 Non Burning, UV Stabilized
Water resistant or rear entry option available.
Dimensions
L=167, W=142, H=40mm, excluding glands and cables
Weight.
Standard model + s packaging = 1200grams
Product Liability
.
This information describes our products. It does not constitute guaranteed properties
and is not intended to affirm the suitability of a product for a particular application. Due to ongoing
research and development, designs, specifications, and documentation are subject to change without
notification. Regrettably, omissions and exceptions cannot be completely ruled out. No liability will be
accepted for errors, omissions or amendments to this specification. Technical data are always specified
by their average values and are based on Standard Calibration Units at 25C, unless otherwise specified.
Each product is subject to the ‘Conditions of Sale’.