Installation Guide for the SolaStat™-Plus-ET
Version 1.2 – July 2011
Page 11
M
OUNTING THE
S
ENSORS
,
C
ONTINUED
Warning
When mounting the sensors please note the following points carefully:
1. Removing or cutting the cladding may void hot water tank warranty.
2. Sensors must not be immersed in water
3. It is recommended that sensor leads be kept 300mm away from mains
and comms cables.
4. Ensure the correct sensors are mounted in the correct place.
5. Failure to properly mount the Tank and Inlet Sensor as prescribed in the
method above can result in:
i. The system not operating at greatest efficiency.
ii. Inaccurate tank and inlet temperature readings on the display.
iii. Inaccurate TOPOUT sensing and causing damage of
components.
6. Failure to correctly mount the Roof Sensor as prescribed in the method
above can result in:
i. The system not operating at greatest efficiency.
ii. Failure to detect Frost conditions. Collector can burst.
iii. Misleading hot water readings on the display.
iv. The pump running on too long.
7. Do not mount sensors in direct rain or sunlight.