Installation Guide for the SolaStat™-Plus-ET
Version 1.2 – July 2011
Page 20
I
NSTALLER
P
ROGRAMMING
,
C
ONTINUED
For example:
Pump Off
6ºC
Pump On
12ºC
Energy Transfer Off in Summer
60ºC
Energy Transfer On in Summer
70ºC
Energy Transfer Off in Winter
40ºC
Energy Transfer On in Winter
55ºC
Frost 4ºC
Topout 80ºC
Step 1
:
Press
to increase or
to decrease Pump Off value to 6.
Step 2
:
Press
to enter value and proceed to next setting. Press
to increase
or
to decrease Pump On value to 12.
Step 3
:
Press
. Press
to increase or
to decrease Energy Transfer Off in
Summer value to 60.
Step 4
:
Press
. Press
to increase or
to decrease Energy Transfer On in
Summer value to 70.
Step 5
:
Press
. Press
to increase or
to decrease Energy Transfer Off in
Winter value to 40.
Step 6
:
Press
. Press
to increase or
to decrease Energy Transfer On in
Winter value to 55.
Step 7
:
Press
. Press
to increase or
to decrease Frost value to 4.
Step 8
:
Press
. Press
to increase or
to decrease Topout value to 80.
Step 9
:
Press
to store the values entered. SolaStat
TM
-Plus-ET will now return to
normal operational mode.