background image

Read  the  following  safety  information  carefully 
before  attempting  to  operate  or  service  the  meter. 
Only  qualified  personnel  should  perform  repairs  or 
servicing not covered in this manual.

2.Safety Information

DO NOT submerge the unit in water.
This  product  is  not  designed  for  use  in  medical 
evaluations.  The  product  can  only  be  used  to 
measure  body  temperature  simply  for  reference. 
They  are  meant  for  industrial  and  scientific 
purposes.  

2-1 Cautions!

2-2 Safety symbols

Dangerous, refer to this manual before using 
the meter.
CE Certification.

This instrument conforms to the following standards:

EN50081-1:1992 Electromagnetic Emissions.
EN50082-1:Electromagnetic Susceptibility.

    Test  were  conducted  using  a  frequency  range  of  80-
1000MHz  with  the  instrument  in  three  orientations.  The 

o

o

average  error  for  the  three  orientations  is 

±

C  )4.0 F(  at 

3V/m  throughout  the  spectrum.  However,  between  300MHz 
and 800Mhz at 3V/m, the instrument may not meet its stated 
accuracy.

            Do not point laser directly at eye . Use 
catution a round reflective surfaces. Keep out of 
reach of children.

Laser Warning Note!

                       2                                    Broad  Temp.      Infrared Thermometer

Summary of Contents for ST 662

Page 1: ...Infrared Thermometer MODEL ST 662 Instruction Manual Broad Temp...

Page 2: ......

Page 3: ...Infrared Thermometer Instruction Manual 662 Version 01 05 APR Broad Temp...

Page 4: ...cations 4 Operation Instructions Unit Diagram 5 Techniques of Infrared Thermometer 6 Maintenance 1 1 Features 2 1 Cautions 4 1 Quick Start 4 2 4 3 C F and Battery Change 5 1 Field of view FOV ratio 5...

Page 5: ...conductor technology Test terminals on circuits Food safety and processing Perform HVAC energy audits 1 2 Applications Thank you for purchasing this infrared thermometer The Infrared Thermometer is a...

Page 6: ...y symbols Dangerous refer to this manual before using the meter CE Certification This instrument conforms to the following standards EN50081 1 1992 Electromagnetic Emissions EN50082 1 Electromagnetic...

Page 7: ...ed at 0 95 Automatically after approx 6 sec 9V 006P IEC6F22 NEDA1604 187g Approx 170x133x45mm 6 69 x5 23 x1 77 Operation Temp 0 50 C 32 122 F 10 90 RH YES Assumes Operation Ambient Temperature of 25 C...

Page 8: ...last reading for about 6 seconds after the trigger is released the word HOLD appears Be sure to consider the target area inside the angle of vision of this instrument The laser is used for aiming only...

Page 9: ...operation and at the same time the low battery symbol will appear To change the 9V battery pull open the unit s handle under the trigger After replacing the battery push back and snap in place LCD Di...

Page 10: ...ed by the optics of the unit The FOV is the ratio of the distance from the target to the target diameter The smaller the target the closer you should be to it When the target diameter is small it is i...

Page 11: ...ergy emitted by the target have fast response and are commonly used to measure moving and intermittent targets targets in a vacuum and targets that inaccessible due to hostile environments geometry li...

Page 12: ......

Page 13: ......

Page 14: ......

Page 15: ......

Page 16: ...ST662 Version 01 07 MAR 3F No 122 Sec 1 Sanmin Road Ban Ciao Taipei 220 Taiwan R O C TEL 886 2 2956 8198 FAX 886 2 2956 7662 http www sentrytek com tw PA05 0000662 01...