The control valve has been pre-programmed from the factory with the correct regeneration cycle program and 

cycle times. The gallon capacity between regeneration can be changed by adjusting the water hardness.  

 

Step 1 

- Press the 

NEXT

 and the 

UP

 Arrow buttons at the same time and hold for 3 seconds. 

Step 2

 - 

Raw Water Hardness:

  Adjust to the correct hardness by pressing the 

UP

 or 

DOWN

 

arrow button. Default setting 20 grains per gallon. Press 

NEXT

 to go to Step 3. 

 

Step 3

 - 

Day Override:

  The factory default setting is 

15 days

. Press 

NEXT

 to go to Step 4. 

Step 4 - Regeneration Time:

 The system regenerates at 

2:00 AM

. The regeneration cycle should 

be set for a time when no water will be used. (Typically this is during the night.) Press the 

UP

 or 

DOWN

 arrow buttons to adjust the regeneration hour. Press 

NEXT

 to adjust the 

regeneration time minutes then press 

NEXT

 to exit programming. 

 

REGEN 

Summary of Contents for 960SM Series

Page 1: ...Single Metered Water Softening System Owner s Manual Series 960SM...

Page 2: ...ontents System Specifications and Warnings 3 Start Up Instructions 4 Series 960 Control Valve Programming 5 Manually Regenerating the Water Softener 8 Bypass Valve Operation 9 Troubleshooting the Cont...

Page 3: ...ontrol valve and fittings are not designed to support the weight of the system or the plumbing Do not use Vaseline oils other hydrocarbon lubricants or spray silicone anywhere A silicone lubricant may...

Page 4: ...n to advance the controller to the next cycle The softener is now in the Fast Rinse cycle Leave the unit in the Fast Rinse cycle for at least five minutes While the system is rinsing manually fill the...

Page 5: ...5 Control Valve Programming Series 960 Control Valve Programming...

Page 6: ...EXT and the UP Arrow buttons at the same time and hold for 3 seconds Step 2 Raw Water Hardness Adjust to the correct hardness by pressing the UP or DOWN arrow button Default setting 20 grains per gall...

Page 7: ...time of day will flash indicating that it needs to be set Step 1 Press SET CLOCK Step 2 Current Time of Day Hours Adjust to the correct hour by pressing the UP or DOWN arrow button Press NEXT to go t...

Page 8: ...the water you may want to manual regenerate the softener using the delayed regeneration method To initiate a delayed regeneration simply push the REGEN button one time Don t hold the button down REGE...

Page 9: ...9 Bypass Valve Operation Normal Operation Bypass Operation Diagnostic Mode Shut Off Mode...

Page 10: ...Connect Meter to three pin connection labeled METER on Circuit Board Remove and reconnect to ensure proper connection Restricted stalled Meter Turbine Remove Meter and check for rotation or foreign m...

Page 11: ...place Damaged Seal and Spacer Stack Assembly Replace Seal and Spacer Stack Assembly Control valve body type and piston type mix matched Verify proper control valve body type and piston type match Foul...

Page 12: ...12 OM A960SM Printed in the USA Version 160915 1...

Reviews: