MODEL: R1M-A1

MODBUS WIRING CONNECTION

R1M

T1
T2
T3
T4

R1M

T1
T2
T3
T4

T1
T2
T3
T4

R1M

CONNECTO

R

RS-232-C

RS-485

*

1

*

1

*

1. Internal terminating resistor is used when the device is at the end of a transmission line.

*

2. Install shielded cables to all sections and ground them at single point.

*

2

FG

RS-485

CONNECTION DIAGRAM

Note: In order to improve EMC performance, bond the FG terminal to ground.
Caution: FG terminal is NOT a protective conductor terminal.

RS-232C

T3
T4

T2

T1

T7

T6

T5

Term.

Resist.

Output

Circuit

When the device is located at the end of a transmission line via twisted-pair cable, 
(when there is no cross-wiring), close across the terminal T2 – T3 with the attached
jumper pin (or with a leadwire).
When the device is not at the end, remove the jumper pin.

*

Power
Circuit

+

Shielded Twisted-pair Cable

To Other
PC Recorders

Jumper*

FG

U (+)
V (–)

POWER

D-SUB CONNECTOR

9

8

7

6

5

4

3

2

1

10

12

11

13

15

14

16
17
18

20

19

21
22
23
24
25

27

26

28
29
30
31
32
33

35

34

36

ch.1

ch.2

ch.3

ch.4

ch.5

ch.6

ch.7

ch.8

COM (–)

ch.9

ch.10

ch.11

ch.12

ch.13

ch.14

ch.15

ch.16

COM (–)

ch.17

ch.18

ch.19

ch.20

ch.21

ch.22

ch.23

ch.24

COM (–)

ch.25

ch.26

ch.27

ch.28

ch.29

ch.30

ch.31

Count Reset Input ch.32

COM (–)

Input Circuit

Input Circuit

A9

A8

A7

A6

A5

A4

A3

A2

A1

A10

A12

A11

A13

A15

A14

A16

B1

:

B16

ch.1

ch.2

ch.3

ch.4

ch.5

ch.6

ch.7

ch.8

ch.9

ch.10

ch.11

ch.12

ch.13

ch.14

ch.15

ch.16

COM (–)

A9

A8

A7

A6

A5

A4

A3

A2

A1

A10

A12

A11

A13

A15

A14

A16

ch.17

CN1

ch.18

ch.19

ch.20

ch.21

ch.22

ch.23

ch.24

ch.25

ch.26

ch.27

ch.28

ch.29

ch.30

ch.31

Count Reset Input ch.32

■ 

FCN TYPE CONNECTOR

■ 

M3 SCREW TERMINALS

CN2

B1

:

B16

COM (–)

Rugghölzli 2
CH - 5453 Busslingen

Tel. +41 (0)56 222 38 18

Fax +41 (0)56 222 10 12

[email protected]

www.sentronic.com

Produkte, Support und Service

SENTRONIC

AG

Summary of Contents for M-system R1M Series

Page 1: ...ss Count value is not saved when the power supply is lost Node address setting Rotary switch 1 F 15 nodes RUN indicator LED Green light blinks in normal conditions COMMUNICATION Baud rate 38 4 kbps Co...

Page 2: ...Reinforced insulation 300 V Input to RS 232 C RS 485 Basic insulation 300 V EXTERNAL VIEW RS 485 Connector Power Terminals Node Address Setting Rotary SW Configurator Jack RUN Indicator LED RS 232 C 9...

Page 3: ...Shielded Twisted pair Cable To Other PC Recorders Jumper FG U V POWER D SUB CONNECTOR 9 8 7 6 5 4 3 2 1 10 12 11 13 15 14 16 17 18 20 19 21 22 23 24 25 27 26 28 29 30 31 32 33 35 34 36 ch 1 ch 2 ch 3...

Page 4: ...ngle Registers X General purpose register within the slave 07 Read Exception Status 08 Diagnostics 09 Program 484 10 Poll 484 11 Fetch Comm Event Counter Fetch a status word and an event counter 12 Fe...

Page 5: ...pe J3 0 No burnout 1 Upscale 2 Downscale 4 I 16 bit integer F 32 bit floating B16 16 byte character 1 Discrete output only 2 Thermocouple input only 3 Trigger contact input for Types GH2 and J3 Only A...

Page 6: ...E A D DATA Decimal DC 20V 20000 5V 5000 1V 10000 0 8V 8000 0 2V 20000 50mV 5000 10mV 10000 Thermocouple Temperature x 10 RTD Temperature x 10 Potentiometer 0 100 2000 0 500 0 1k 0 10k BIT NAME DESCRIP...

Page 7: ...CRC 270 to 1000 C 0X13 J IC 210 to 1200 C 0X14 T CC 270 to 400 C 0X15 B RH 100 to 1820 C 0X16 R 50 to 1760 C 0X17 S 50 to 1760 C 0X18 C WRe 5 26 0 to 2320 C 0X19 N 270 to 1300 C 0X1A U 200 to 600 C 0...

Page 8: ...6 1 81 DIN RAIL 35 mm wide FCN TYPE CONNECTOR T1 T2 T3 T4 T5 T6 T7 104 4 09 10 39 105 4 13 14 55 163 6 42 165 6 50 175 6 89 3 5 20 dia MTG HOLES FOR WALL MOUNT FCN TYPE I O CONNECTOR 6 24 40 1 57 40 1...

Page 9: ...istance between the PC and the R1Ms is long insert an RS 232 C RS 485 Converter for isolation RS 232 C RS 232 C RS 485 Converter model R2K 1 Specifications are subject to change without notice Ruggh l...

Page 10: ...ed to the unit and TDK Model ZCAT3035 1330 or equivalent for the RS 232C cable are recommended The equipment must be installed such that appropriate clearance and creepage distances are maintained to...

Page 11: ...ith the attached jumper pin or with a leadwire When the device is not at the end remove the jumper pin Power Circuit Shielded Twisted pair Cable To Other I O Modules Jumper FG U V POWER D SUB CONNECTO...

Page 12: ...tor is used when the device is at the end of a transmission line 2 Install shielded cables to all sections and ground them at single point 2 FG RS 485 CHECKING 1 Terminal wiring Check that all cables...

Page 13: ...W TERMINALS FCN TYPE CONNECTOR T1 T2 T3 T4 T5 T6 T7 104 4 09 10 39 105 4 13 14 55 163 6 42 165 6 50 175 6 89 3 5 20 dia MTG HOLES FOR WALL MOUNT FCN TYPE I O CONNECTOR 6 24 40 1 57 40 1 57 Connector P...

Reviews: