9. Troubleshooting
The infrared control unit is equipped with diagnostic software which monitors the
system status when switching on and during operation. As soon as the diagnostic
software identifies an error, the infrared control unit switches the heating system off.
Error
Description
Cause / rectification
E1
Safety temperature
limiter
The sensor included in the delivery does
not have a safety temperature limiter.
Check that the ex-works wire jumper is
secure.
E3
Room sensor interruption Check the cabin sensor cable for dam-
age and that the terminal points are con-
nected properly
E4
Room sensor short-
circuit
Check the cabin sensor cable for dam-
age.
E5
Foil sensor interruption
If you are not using foils or heating plates,
the ex-works dummy sensor must stay
in position.
If you are using a foil sensor, check the
cable for damage and check that the ter-
minals are connected properly.
E6
Foil sensor short-circuit
If you are using a foil sensor, check the
cable for damage and check that the ter-
minals are connected properly.
E7
Foil excess temperature If you are not using foils or heating plates,
the ex-works dummy sensor must stay
in position.
If you are using a foil sensor, check the
cable for damage and check that the ter-
minals are connected properly.
►
If the error still persists despite performing the measures described
above, please contact your supplier.