4. Installation
The infrared control unit can either be surface-mounted or recess mounted.
4.1. Preparing for surface mounting
To mount the control unit on a surface, you need to make cable bushings in the
cabin wall. Refer to the following figure for the positions.
49
85
17,5
34
49
65
80,5
1
7
2 3 4 5 6
1
Sensor cable outlet
2
Mains power line
3
Heater/foils outlet
4
Free
5
Free
6
Light outlet
7
Cable shaft
►
Caution:
If the cable is fed down-
wards through the cable shaft
7
, the
sensor cable must be fitted with ad
-