Technical Data
Dimensions: L x W x H: 238 x 195 x 73,50 mm
Environmental conditions:
Storage temperature:
-25°C to + 70°C
Ambient temperature:
-10°C to + 40°C
Humidity:
max. 95 %
Minimum temperature stability of the connecting li-
nes:
Heating system, lighting circuits, stove and bench lines
are heat-resistant to at least 150°C .
Maximum lengths of lines:
stove sensor:
3 m
bench sensor:
3 m
Control:
Switching voltage / three-phase 3N:
400 V
Frequency:
50 Hz
Switching capacity / heating AC 1:
3 x 3 kW
Switched current each phase /
heating AC 1:
13 A
Switching capacity /
steam generator AC 1:
3 kW
Switching capacity /
steam generator AC 1:
13 A
Nominal voltage:
230 V
Min. / max. pick-up capacity:
4,3 / 6,3 VA
Degree of protection (splash-proof):
IP X4
Connection to the main circuit as permanent wiring
(non-detachable connection).
Steam generation:
On/ Off time:
approx. 200 s
Min. / max. inrush impulse:
approx. 10 / 200 s
Light:
AC1 switched current:
1A
Edition: 07-2012
Ident-No. ,1511044
Thermal safety:
Stove sensor with overtemperature protector,
shutdown temperature 139°C.
Automatic shutdown after, at the maximum of 6 hours
(depending on the factory setting).
Dual sensor system with temperature controls via stove
and bench respectively.
Optional sauna door safety-monitor when the desired
time has been set:
• Without heating operation:
- The desired time set will be cancelled on opening
of the sauna door.
• With heating operation at temperatures below
40°C:
- The heating will be shut down.
- Restarting the control is necessary.
• With heating operation at temperatures above
40°C:
- The heater will shut down, if the sauna door remains
opened for more than 5 seconds.
- Heating continues on closing the sauna door.
Range of adjustment:
Sauna operation:
40-125 degrees Celsius
above
the
stove.
Steam operation:
40-65 degrees Celsius
at
the
bench.
Steam generator:
00 - 100 % steam output
Selected start-time:
in 15 minute increments
Min. of selected start-time:
15 minutes
Max.of selected start-time:
23 hours 45 min.
Duration of heating:
Automatic shutdown
after
6
hours*.
* If used in apartment buildings, hotels, or similar buil-
dings, the operational timeframe has to be limited to
12 hours.
• 12 •
WE DO IT FIRST.
Instructions for installation and use
P. 12/14
Summary of Contents for K3-NEXT
Page 56: ...4 3 2 1 5 6 7 8 9 Figura 4 Figura 5 Istruzioni per uso e montaggio P 14 14 WE DO IT FIRST...
Page 84: ...4 3 2 1 5 6 7 8 9 Bild 4 Bild 5 Monterings och bruksanvisning S 14 14 WE DO IT FIRST...
Page 98: ...4 3 2 1 5 6 7 8 9 Obr zek 4 Obr zek 5 WE DO IT FIRST N vod k mont i a pou it s 14 14...
Page 99: ...WE DO IT FIRST NOTIZEN APPUNTI NOTES NOTE NOTITIES...