1 Operating modes
You have two operating modes: sauna and steam
operation.
You can start the operating modes directly via the Quick-
Start feature (refer to chapter 6 and 7) or after the set
desired time has elapsed - time until the stove turns
on (refer to chapter 8 und 9).
During sauna operation
you will have dry heat at
your disposal. The temperature is high, the humidity
is low.
During steam operation
the temperature in the sauna
cabin will be lower, but the relative humidity will be
significantly higher.
Steam operation at temperatures below 65°C
only:
If you adjust the steam using the knob
6
while the
temperature is above 65°C, the display
3
will indicate
the message:
Hot
• The control will shut down the heater.
• The steam generator will be switched on once the
temperature reaches 65°C.
2 Displays
Self-testing of the control (display
flashes).
Heater is running.
Heater is not running.
Steam generator is running.
Steam generator is not running.
Door of the sauna cabin is open
(applies to optional sauna door
safetymonitor
only).
Temperature too high for
steam generator to operate.
Low-water level in steam generator
(applies to units with a connection to
a water-shortage indicator only).
3 Optional sauna door
safety-monitor
To offer protection from fire hazards, the sauna door
will be monitored after the desired start-time has been
set (time until the stove turns on).
To prevent somebody from entering the cabin after the
desired start-time has been set, and perhaps place
an object on top of the stove, the control has been
equipped with a safety shutdown, which will respond
according to the operational status:
3.1 Operational status -
stove does not heat
The desired start-up time has been set. Heater is
not running yet. The sauna door is opened:
• You will hear a repeated beeping sound,
• the display
3
will indicate the message “
door”
,
• the desired start-time will be cancelled.
After closing the sauna door, you will have to re-
enter the desired start-time.
3.2 Operational status - stove is heating
The desired start-up time has elapsed. The heater
is running.The sauna door is opened:
1. The temperature is below 40°C:
• You will hear a repeated beeping sound,
• the display
3
will indicate the message
“door”
,
After closing the sauna door, you will have to re-
enter the desired start-time or you will have to
restart the control.
2. The temperature is above 40°C:
If you quickly open the sauna door (for less than 5
seconds) no message will be indicated. If the sauna
door is opened for longer than 5 seconds:
• you will hear a repeated beeping sound,
• the signal lamp
2
will flash,
• the heater will be turned off,
• the display
3
will indicate the message
“door”
,
After closing the sauna door, the heater will be
turned on again.
• the beeping stops,
• the displayed message
“door”
disappears.
Instructions for use for the user
P. 7/14
WE DO IT FIRST.
EN
Summary of Contents for K3-NEXT
Page 56: ...4 3 2 1 5 6 7 8 9 Figura 4 Figura 5 Istruzioni per uso e montaggio P 14 14 WE DO IT FIRST...
Page 84: ...4 3 2 1 5 6 7 8 9 Bild 4 Bild 5 Monterings och bruksanvisning S 14 14 WE DO IT FIRST...
Page 98: ...4 3 2 1 5 6 7 8 9 Obr zek 4 Obr zek 5 WE DO IT FIRST N vod k mont i a pou it s 14 14...
Page 99: ...WE DO IT FIRST NOTIZEN APPUNTI NOTES NOTE NOTITIES...