![Sentiotec just sauna combi Instructions For Installation And Use Manual Download Page 46](http://html1.mh-extra.com/html/sentiotec/just-sauna-combi/just-sauna-combi_instructions-for-installation-and-use-manual_1244682046.webp)
WORLD OF WELLNESS
Instructions for installation and use
p. 46/50
13. Troubleshooting
13.1. Error messages
The sauna control unit is equipped with diagnostic software which monitors
system statuses at start-up and during operation. As soon as the diagnostic
software identiies an error, the sauna control unit switches the sauna heater off.
Errors are indicated by a recurring warning tone emitted by the power unit and by
the lashing lights on the LED wheels
c
and
f
. Furthermore, the error number
is displayed with the help of the power level display
3
. The number of LEDs on
it which are lashing indicates the error number. The following table describes
the possible errors and their causes. If necessary, tell the error number to your
customer service specialist.
Switch the sauna control unit off on the power unit using the ON/OFF switch
A
and rectify the error before switching the sauna control unit on again.
Error
Description
Cause / rectiication
01
Safety shut-off
An object has been placed on the sauna
heater. Remove any objects before start-
ing up the sauna heater again.
02
Excess temperature fuse
The maximum temperature of 139 °C
has been exceeded above the heater.
03
Communication error
No power unit has been connected,
or the contact is poor.
04
Heater sensor error
Defective heater sensor, poor contact,
or short circuit.
05
Foil sensor error
Defective foil sensor, poor contact,
or short circuit.
06
Bench sensor error
Defective bench sensor, poor contact,
or short circuit.
07
Humidity sensor error
Defective humidity sensor, poor contact,
or short circuit
08
Foil sensor excess tem-
perature
The maximum foil temperature of
100 °C was exceeded.