![Sentiotec just sauna combi Instructions For Installation And Use Manual Download Page 24](http://html1.mh-extra.com/html/sentiotec/just-sauna-combi/just-sauna-combi_instructions-for-installation-and-use-manual_1244682024.webp)
WORLD OF WELLNESS
Installation instructions, only for experts
p. 24/50
5.10.
Connecting the ilm sensor (optional)
1. Guide the wires for the sensor through the cable bushing
5
into the low-
voltage connection area
1
.
2. Connect the wires for the sensor to the terminals labelled “
FF
” in terminal
strip
2
.
5.11. Connecting the safety shut-off device
EN 60335-2-53 states that sauna control units with a remote start or preset timer
function may only be used for operating and regulating a sauna heater which
has satisied the combustion test described in paragraph 19.101. Alternatively,
a suitable safety shut-off device can be installed in or above the heater. This shuts
the sauna heater off when objects, e.g. a towel, are placed on the sauna heater.
To install the safety shut-off device, perform the following steps:
1. Install the safety shut-off device in accordance with the operating instruc-
tions for the device.
2. Guide the wires for the safety shut-off device through the cable bushing
7
into the low-voltage connection area
1
.
3. Connect the wires for the temperature sensor to the terminals labelled “
OSG
”
in terminal strip
2
.
When the remote start function is deactivated, you may also use the
sauna control unit just sauna with a safety shut-off device. In this case,
bridge terminal “
OSG
” in the low-voltage connection area
1
using
a wire jumper.