Instructions for use for the user
p. 38/60
10.4. Combi-mode
Starting combi-mode
1. Use rotary selector
1
to select the temperature icon. Then press it
briefly to confirm.
►
The “Humidity” submenu opens and the setpoint value for
the humidity appears underlined in the display.
2. Press rotary selector to change the value.
►
The value is now highlighted in green and can be changed.
► Press the rotary selector again to confirm the setting.
3. Move the cursor (underscore
) to the right to “On” and briefly press
the rotary selector.
►
The vaporizer is switched on and begins to heat up.
► The colour of the humidity icon in the notification area changes
to blue.
►
You automatically exit the “Humidity” menu item.
Switching off combi-mode
4.
To switch off the vaporizer, repeat points 1 and 3.
► Instead of “On”, “Off” is displayed.
►
To exit the submenu, move the cursor to the “Back” icon on
the left and confirm with the rotary selector.
► The vaporizer switches off.
The vaporizer can only be started when the sauna heater is switched on.
The maximum humidity that can be set depends on the temperature of
the sauna. The higher the sauna temperature, the lower the maximum
humidity level which can be set (see characteristic curve).
Exception:
Vaporizer single mode is activated (see
“9.1. Technician
menu” on page 33
). The vaporizer can also be operated here without
the sauna heater, with the maximum humidity depending on the current
sauna room temperature.
If the sauna control unit is used without a humidity/temperature sensor
(FTS2), cyclic mode is activated. If the sauna room temperature is less
than 30 °C, the vaporizer is activated continuously for a preset time
(10 minutes by default). Normal cyclic mode then starts.
Summary of Contents for HC4-B-RS485
Page 361: ...NOTIZEN APPUNTI NOTES NOTE NOTITIES...
Page 362: ...NOTIZEN APPUNTI NOTES NOTE NOTITIES...