EN
Installation instructions, only for experts
p. 25/60
5.13. DMX output (optional)
1.
Guide the DMX connection cables for the heater sensor through the cable
gland
7
into the low-voltage connection area.
2. Connect the DMS connection cables in accordance with the designations
on terminal strip
f
.
-
DMX A
(DATA +)
-
DMX B
(DATA -)
-
GND
(ground/shield)
Four different DMX protocols are supported, which are output at the same time
on the DMX output:
1.
8-bit RGBW
2.
16-bit RGBW
3. 8-bit hue value saturation (such as for COLLAXX coloured light devices)
4. 8-bit hue saturation value
Use the following address overview to integrate your coloured light unit into
the sauna control unit.
RGBW_8BIT
●
Start address: Channel 1
►
Channel light group 1:
1
►
Channel light group 2:
5
►
Channel light group 3:
9
►
Channel light group 4:
13
RGBW_16BIT
●
Start address: Channel 17
►
Channel light group 1:
17
►
Channel light group 2:
25
►
Channel light group 3:
33
►
Channel light group 4:
41