5. Electrical connection
Observe
Fig. 2
and
Fig. 6
(figures chapter)
ATTENTION!
Damage to the unit
●
The sauna control unit may only be used for operating and controlling 3 heat-
ing circuits with a maximum heating capacity of 3.5 kW per heating circuit.
The maximum evaporator capacity totals 3.5 kW. Optionally with an additional
power module the switching capacity can be increased from 10.5 kW to
18 kW / 30 kW.
Please observe that in the event of a guarantee claim, a copy of the bill
from the electrician performing the work must be presented.
●
Work on the sauna control unit may only be performed when the power has
been disconnected.
● There must be a fixed connection for the electrical power supply.
●
An all-pole disconnecting device with full cut-off compliant with overvoltage
category III must be fitted on-site.
●
Before installing the sauna control unit, take note of the requirements in the
installation and operation manual of the sauna heater manufacturer. The sauna
control unit has a connection area for extra-low voltage
4
and a connection
area for 230 V connections
i
(
Fig. 2
).
●
Observe the connection diagram (
Fig. 6
).
●
Clamp all earth conductors to the earth conductor panel
d
(
Fig. 2
).
5.1. Connecting the supply line, heater
●
Guide the supply and heating system lines through the installation open-
ings
e
,
f
(connection area for 230 V / 400 V I) into the housing lower
part
1
and connect according to the circuit diagram (
Fig. 6
) to the termi-
nal
j
with a maximum tightening torque of 1.2 Nm.
Observe the following points when connecting the power to the sauna control unit:
● Installation may only be performed by a qualified electrician or similarly quali
-