Installation instructions, for professionals only
p. 17/44
5.6. Connecting heater sensor F1
1. Guide the wires for the heater sensor through the cable bushing 9 into the
low-voltage connection area
5
.
2. Connect the red wires for the heater sensor to the terminals labelled “
r-r
”
in terminal strip
4
.
3. Connect the white wires for the heater sensor to the terminals labelled “
w-w
”
in terminal strip
4
.
5.7. Installing bench sensor F2 (optional)
1. Guide the wires for the bench sensor through the cable bushing
7
into the
low-voltage connection area
5
.
2. Connect the wires for the bench sensor to the terminals labelled “
sw-br
” in
terminal strip
4
.
5.8. Installing humidity temperature sensor FTS2 (optional)
1. Guide the wires for the sensor through the cable bushing
7
into the low-
voltage connection area
5
.
2. Connect the wires for the temperature sensor lines to the terminals labelled
“
sw-br
” in terminal strip
4
.
a. Connect the black wire to terminal “
sw
”.
b. Connect the brown wire to terminal “
br
”.
3. Connect the wires for the humidity sensor to the terminals labelled “
or-rt-gn
”
in terminal strip
4
.
c. Connect the orange wire to terminal “
or
”.
d. Connect the red wire to terminal “
rt
”.
e. Connect the green wire to terminal “
gn
”.