Installation instructions, for professionals only
p. 20/70
4.2. Installing the control panel
The control panel
2
is installed on the cabin wall at a maximum distance of
10 metres from the power supply unit
1
(see
Fig. 4
).
Installation requires the use of a standard jigsaw, for example,
to cut out the recess for the control unit. The control panel can be
either inside or outside the cubicle.
* For installation inside a sauna cubicle, a minimum clearance of 30 cm
from the cubicle roof must be maintained (see
Fig. 4
).
ATTENTION!
Damage to the unit
●
The control unit
2
of the sauna control unit is splash-proof (protection class
IP IPX4).
●
Work on the control panel may only be carried out using a standard screwdriver.
Using a cordless screwdriver may cause irreparable damage to the housing.
Power supply
unit
External view
Control
panel
1
2
Fig. 4 Control panel position
*
for assembly inside the cabin
min. 30 cm
*