SAFETY AND PRECAUTIONS

 

Read all information, the datasheet, mounting instructions and wiring scheme 
before working with the product. For personal and equipment safety, and for 
optimum product performance, make sure you entirely understand the contents 
before installing, using, or maintaining this product.

 

For safety and licensing (CE) reasons, unauthorised conversion and / or modifications 
to the product are not permitted.

The product must not be exposed to abnormal conditions, such as: extreme 
temperatures, direct sunlight or vibrations. Chemical vapours with high concentration 
in combination with long exposure times can affect the product performance. Make 
sure the work environment is as dry as possible; check for condensation spots.

 

All installations shall comply with the local health and safety regulations and local 
electrical codes. This product can only be installed by an engineer or a technician 
who has an expert knowledge of the product and safety precautions.

 

Avoid contacts with energised electrical parts; always treat the product as if it 
is life. Always disconnect the power source before connecting the power cables, 
servicing or repairing the product.

 

Always verify that you apply appropriate power supply to the product and use wires 
with appropriate size and characteristics. Make sure that all the screws and nuts are 
well tightened and fuses (if any) are fitted well.

 

Recycling of equipment and packaging should be taken into consideration and 
disposed in accordance with local and national legislation / regulations.

 

In case there are any questions that are not answered, please contact your technical 
support or consult a professional.

MTV-1/010-NA

230 VAC 
POTENTIOMETER 

Summary of Contents for MTV-1/010-NA

Page 1: ...Mounting and operating instructions MTV 1 010 NA 230 VAC POTENTIOMETER ...

Page 2: ...AUTIONS 3 PRODUCT DESCRIPTION 4 ARTICLE CODES 4 INTENDED AREA OF USE 4 TECHNICAL DATA 4 STANDARDS 4 WIRING AND CONNECTIONS 4 MOUNTING INSTRUCTIONS IN STEPS 5 TRANSPORT AND STOCK KEEPING INFORMATION 6 WARRANTY INFORMATION AND RESTRICTIONS 6 MAINTENANCE 7 MTV 1 010 NA 230 VAC POTENTIOMETER ...

Page 3: ...ble check for condensation spots All installations shall comply with the local health and safety regulations and local electrical codes This product can only be installed by an engineer or a technician who has an expert knowledge of the product and safety precautions Avoid contacts with energised electrical parts always treat the product as if it is life Always disconnect the power source before c...

Page 4: ...al is required For indoor use only TECHNICAL DATA Power supply 230 VAC 10 50 60 Hz Output 0 10 VDC Load min 1 kΩ Consumption max 8 mA Enclosure External ASA white ivory RAL 9010 IP54 according to EN 60529 Internal polyamide white ivory RAL 9010 IP44 according to IEC 60335 Operating ambient conditions temperature 0 40 C rel humidity 100 rH non condensing Storage temperature 10 55 C STANDARDS Low Vo...

Page 5: ...the external enclosure 3 Dothewiringaccordingtothewiringdiagram seeFig 1 Wiringandconnections Fig 1 Wiring and connections Power supply Output voltage 4 Mount the internal enclosure into the wall according to the mounting dimensions shown in Fig 2 Mounting dimensions inset mounting Fig 2 Mounting dimensions inset mounting 26 33 50x50 82 89 7 NOTE Mount the unit so that the terminal block and conne...

Page 6: ... the external one and fix it using the screws and washers included in the set NOTE Mount the unit so that the terminal block and connections are at the lower side 7 Mount back the cover using the nut 8 Put back the knob and turn it to off position 9 Turn on the power supply NOTE A 5 mm hole can be drilled at the bottom of the external enclosure to drain the condensed water TRANSPORT AND STOCK KEEP...

Page 7: ...s maintenance free If soiled clean with a dry or dampish cloth In case of heavy pollution clean with a non aggressive product In these circumstances the unit should be disconnected from the supply Pay attention that no fluids enter the unit Only reconnect it to the supply when it is completely dry MTV 1 010 NA 230 VAC POTENTIOMETER ...

Reviews: