MIW-RDCV-EN-002 - 27 / 04 / 2017
9 - 17
OPERATING INSTRUCTIONS
Choosing the operating mode
To choose the desired operating mode, press the up and down
buttons
simultaneously in order to access the Setup mode. The decimal point after the values
indicates that the unit is in Setup Mode.
The display shows “RUN”. To change the run mode, press the
button. Use the up
and down
buttons to select “1” for automatic mode or “0” - for manual mode.
To save the selected mode press
for 4 seconds. The display will show "888" for a
few second to indicate that the value is stored in the memory. Press the up and
down
buttons simultaneously again in order to exit the Setup mode.
■
AUTOMATIC MODE:
In
Automatic mode
the RDCV is a “master” device, i.e. it needs to be connected to
a sensor via Modbus RTU in order to operate and control the environment based
on the information received by the sensor. If no sensor is connected, the display
will show “...” and the RDCV will not work. The sensor needs a few seconds in order
to take samples from the environment.
Automatic mode
Modbus RTU
0—10 VDC /
0—20 mA / PWM
RST
Room sensor
RDCV
Residential Digital Controller
EC fan / valve actuator
►
Adjustment of parameters:
If necessary, some parameters, such as setpoints, can be adjusted (see
Table 1
“
Adjustable parameters
"). To do so, you can either use the 3-button interface
to enter the menu mode (see
USER MENU STRUCTURE
below), use the free
downloadable 3SModbus software to enter the Modbus registers from a
computer (see Modbus registers maps), or use the Sensistant configurator.
►
Operating the RDCV in automatic mode:
The RDCV can be switched on and off by pressing and holding the
button for 4
seconds. The decimal point on the display indicates that the unit is in Stand-by mode.
When the RDCV is operational , you can toggle the display between the value measured
by the sensor and the output value (percentage) by pressing the
button.
RDCV
RESIDENTIAL HVAC
CONTROLLER