ELECTRONIC CONTROL PANEL 

 

Page 8 

 

 

display

 

 

 

POWER  led

:  lights  up  when  electrical  power  is 

applied 

 

 

DOWN button

: to decrease the value of the 

parameter 

 

 

UP button

: to increase the value of the parameter 

 

 

SCROLL  button

:  to  advance  to  the  next 

parameter 

 

 

POWER-UP 

 
After  power-up,  the  display  will  show  the  installed 
software version for 5 seconds, f.e.: 
 
 
 
Afterwards it will automatically  revert  back to the  service 
display. 
 
The POWER led will light up. 
 
 

POWER FAILURE 

 

In  the  event  of  a  power  failure,  the  program  will  remain 
stored in the NOVRAM® during an undefined period, while 
an  incorporated  SuperCap  (capacitor)  will  maintain  the 
correct  time  of  day  during  a  period  of  several  hours; 
consequently, in case of prolonged power failure, the time 
of day might not be maintained; if this happens, the time 
of  day  indication  will 

flash

  when  the  power  supply  is  re-

established,  indicating  that  the  time  of  day  needs  to  be 
set. 
 

When the power failure occurs during the execution of an 
automatic regeneration, the control valve will immediately 
return to the service position; when the power supply is re-
established,  the  control  valve  will  stay  in  the  service 
position  for  60  sec.  and  restart  a  complete  regeneration 
from the beginning. 
 
 
 
 

TIMER FAILURE 

 

In  the  event  of  a  timer  failure,  the  display  will  show  the 
message: 
 
 
 
In such case, entering one of the programming levels can 
possibly  solve  the  problem.  However  if  the  problem 
persists, professional service is required. 
 
 

SERVICE MODE 

 
In 

service mode 

the

 

display shows the time of day and the 

remaining number of days: 
 
 
 
 

REGENERATION MODE 

 
In 

regeneration  mode 

the

 

display  shows  the  actual 

regeneration  cycle  and,  where  relevant,  the  total 
remaining regeneration time and remaining cycle time: 
 
 
 
 
 
 
 

The control valve can be 

reset to service mode

 at any time 

by  pressing  the 

scroll 

  button,  as  such  manually 

advancing it through the regeneration cycles. 

 
 

CHECKING THE FLOW METER 

 
In case of water usage, the remaining capacity counter  in 
the  service  display  will  count  back  per  unit,  i.e.  per  litre; 
furthermore  the  water  usage  indicator  will  revolve.  This 
way  the  correct  functioning  of  the  water  meter  can  be 
verified. 
 
 

MANUAL REGENERATION 

 

It is possible to manually initiate a regeneration. 
1.

 

Press the 

scroll

 

 button repeatedly until the display 

shows: 

 
 
 

 

If  the  control  valve  is  left  in  this  position,  the 
countdown  timer  will  countdown  to  0  sec  and 

start a regeneration.

 

 

To  cancel  this  mode,  press  the 

scroll

 

  button 

before  the  countdown  timer  has  reached  0  sec; 
the control valve will return to the service mode. 

 

 

Service Required  

 

 

EU4PB  

 

 

Regen in 10 sec 

 

20:51    1000L - 

 

BRINE FILL

 

Regen Pending

 

Rgn:XXX CycY:ZZZ

 

Summary of Contents for Eco

Page 1: ...OM ENG SentenciaEco Rev2010 10 O OW WN NE ER R S S M MA AN NU UA AL L Eco Eco WATER SOFTENER SYSTEM ...

Page 2: ...ll in the following data INSTALLATION RECORD Serial Number _______________________________________________ Model ________________________________________________________ Water Hardness inlet _______________________________________ Water Hardness outlet _____________________________________ Water Pressure inlet ________________________________________ Date of Installation __________________________...

Page 3: ... by a competent person aware of the local codes in force All plumbing and electrical connections must be done in accordance with local codes Before setting up the water softener make sure to check it for any externally visible damage do not install or use when damaged Use a hand truck to transport the water softener To prevent accident or injury do not hoist the water softener over your shoulder D...

Page 4: ...outdoor elements such as direct sunlight or atmospheric precipitation do not install the water softener too close to a water heater keep at least 3 m of piping between the outlet of the water softener and the inlet of the water heater water heaters can sometimes transmit heat back down the cold pipe into the control valve always install a check valve at the outlet of the water softener ELECTRICAL ...

Page 5: ...ater softener untreated water outlet of water softener treated water house application treated water 1 Screw the factory bypass onto the elbow connections of the water softener make sure to install the gasket seals Tighten the nuts firmly by hand 2 Screw the brass connection kit with nuts onto the factory bypass make sure to install the gasket seals Tighten the nuts firmly by hand 3 Connect the ma...

Page 6: ...o the drain solenoid of the control valve secure it by means of a clamp 2 Run the drain hose to the drainage system and connect it to the stand pipe assuring sufficient air gap This drain line operates under pressure so it may be installed higher than the water softener 3 Connect a 13 mm hose to the overflow elbow located at the back side of the water softener secure it by means of a clamp 4 Run t...

Page 7: ...he bypass valve 2 open the outlet valve 3 slowly open the inlet valve 6 After 2 3 minutes open a cold treated water faucet nearby the water softener and let the water run for a few minutes until all air is purged from the installation close the tap 7 Check the water softener and all hydraulic connections for leaks BRINE CABINET 8 Add water conditioner salt to the brine cabinet ELECTRONIC CONTROL P...

Page 8: ...ginning TIMER FAILURE In the event of a timer failure the display will show the message In such case entering one of the programming levels can possibly solve the problem However if the problem persists professional service is required SERVICE MODE In service mode the display shows the time of day and the remaining number of days REGENERATION MODE In regeneration mode the display shows the actual ...

Page 9: ... the display will show Press the up button or down button to set the language 2 Press the scroll button again the display will show Press the up button or down button to set the time of day 3 Press the scroll button again the display will show Press the up button or down button to set the hardness of the incoming untreated water Language English Set time 20 51 Set hardn XX f ...

Page 10: ...o the house application refill swimming pool irrigation WITH FACTORY BYPASS optional SERVICE POSITION inlet valve to water softener is OPEN outlet valve from water softener is OPEN BYPASS POSITION inlet valve to water softener is CLOSED outlet valve from water softener is CLOSED WITH 3 VALVE BYPASS SYSTEM not included SERVICE POSITION bypass valve is CLOSED inlet valve to water softener is OPEN ou...

Page 11: ...t to break it apart 3 pour warm water over the top of the salt to dissolve it BRINE CABINET To retain the appearance of the water softener simply wipe it with a damp cloth or clean it with a mild soap solution never use abrasive cleaners ammonia or solvents RESIN CLEANER Other contaminants f e iron present in the feed water can cause the resin bed to foul up resulting in a loss of softening capaci...

Page 12: ... draw brine Improper brine refill time setting Verify that brine refill time corresponds to the proper salt level and amount of resin Missing brine refill flow control Verify that flow control is installed and properly sized Leak from control valve to brine cabinet Clean or replace plunger and solenoid diaphragm of refill solenoid Salt taste in treated water Excessive water in brine tank Refer to ...

Page 13: ...or brine restrictor Clean injector and or brine restrictor Plugged injector filter Clean injector filter Restricted drain line Verify drain line for kinks or restrictions Restricted brine line Verify brine line for kinks or restrictions Leak in brine line Verify brine line and connections for air leakage No water in brine tank Refer to problem Control valve fails to refill brine tank Backwash sole...

Page 14: ...93 Salt usage per regeneration kg 3 1 4 1 9 2 5 3 3 4 0 Exchange capacity per kg salt m x f 41 Exchange capacity per kg salt m x d 23 Recommended maximum service flow m hr 1 1 1 5 2 0 2 6 3 2 Rinse water usage per regeneration 3 bars Ltr 3 59 80 92 116 141 2 Indicative numbers performances depending on operating conditions and water quality 3 Maximum salt water usage as brining is proportional min...

Page 15: ...32 44 58 75 Salt usage per regeneration kg 3 1 4 1 9 2 5 3 3 Exchange capacity per kg salt m x f 41 Exchange capacity per kg salt m x d 23 Recommended maximum service flow m hr 1 1 1 5 2 0 2 6 Rinse water usage per regeneration 3 bars Ltr 3 97 118 149 185 2 Indicative numbers performances depending on operating conditions and water quality 3 Maximum salt water usage as brining is proportional mini...

Page 16: ...NOTES Page 16 ...

Page 17: ......

Page 18: ......

Page 19: ......

Page 20: ......

Reviews: