START-UP
Page 7
PRESSURIZING
1.
Put the bypass system in 'bypass' position.
2.
Make sure the electronic controller of the water
softener is 'in service'.
3.
Open the mains water supply.
4.
Open a cold treated water faucet nearby the water
softener and let the water run for a few minutes until
all foreign material that may have resulted from the
installation is washed out; close the tap.
5.
Gently pressurize the water softener, by putting it
into service:
factory bypass:
1.
open the 'outlet' valve;
2.
slowly open the 'inlet' valve.
3-valve bypass:
1.
close the 'bypass' valve;
2.
open the 'outlet' valve;
3.
slowly open the 'inlet' valve.
6.
After 2-3 minutes, open a cold treated water faucet
nearby the water softener and let the water run for a
few minutes until all air is purged from the
installation; close the tap.
7.
Check the water softener and all hydraulic
connections for leaks.
BRINE CABINET
8.
Add water conditioner salt to the brine cabinet.
ELECTRONIC CONTROL PANEL
9.
Program the electronic controller (refer to section
'ELECTRONIC CONTROL PANEL').
INITIATE A REGENERATION
10.
Manually initiate a regeneration, by pressing the
scroll
button repeatedly until the display shows:
11.
Leave the water softener in this position; the
countdown timer will countdown to 0 sec and start a
regeneration.
Regen in 10 sec