No.11S031-03
27
STC-CL500E/CLC500E
Users guide Rev. 1.3
Command No.
14H:
UART[7..0]
D7 to D2: No function
Sets always as "000000"
D1 to D0:
00: 38,400bps,
01: 9,600bps,
10 to 11: No function
(Prohibited setting. Do not set these values)
20H:
SVR[7..0]
21H:
SVR[15..8]
22H:
SHR[7..0]
23H:
SHR[15..8]
24H:
PSR[7..0]
25H:
PSR[15..8]
D[7..0]
the value of SHR[] is 0.
Sets the preset shutter speed for electronic shutter.
Exposure time (shutter speed) = SVR[15..0] x (1H cycle) + SHR[15..0] x (1CLK cycle)
The camera works with the shutter off (Frame exposure) when this value sets 0 and
Communication mode
Command descriptions
[The communication mode] Initial data: 01H
Sets the communication mode.
[The exposure time (H) of the electronic shutter]
Initial data: SVR[15..0] = 0, data range: 0 to 4095
The camera works with minimum shutter speed when this value sets 0 and
the value of SHR[] is 1 to 600.
Automaticaly sets 4095 when sets more then 4095.
[The exposure time (CLK) of the electronic shutter]
The camera works with the shutter off (Frame exposure) when this value sets 0 and
the value of SVR[] is 0.
Initial data: SHR[15..0] = 0, data range: 0 to 1923
Sets the preset shutter speed for electronic shutter.
Exposure time (shutter speed) = SVR[15..0] x (1H cycle) + SHR[15..0] x (1CLK cycle)
The camera works with minimum shutter speed when this value sets 1 to 600 and
the value of SVR[] is 0.
The camera works with the full scanning when (PSR[]
+
PWR[]) is more than 2058.
Automaticaly sets 1923 when sets more then 1923.
[The start line of the variable partial scanning]
Sets the start line of the variable partial scanning.
Actual start line of the partial scanning = this value + 1
Initial data: PSR[15..0] = 00, data range: 0 to 2057
Automaticaly sets 2057 when sets more then 2057.
D7 D6 D5 D4 D3 D2 D1 D0