Monochrome Field Update Line Scan Camera Link Series
Command No.
Bit No.
Command Description
CBh.0-1
【
Communication Mode
】
Initial Data: 0
To set the Specific Communication Mode.
Please set this parameter ”ON” , when external sync does not input camera.
0:OFF Normal Mode (Communication just only work with external sync)
1:ON Specific Communication Mode (Internal Sync mode without video image output)
2-3:Invalid
E0h.4
【
Clear FFC(Gain) RAM
】
Initial Data: Write Only
To clear the FFC Gain data on the RAM.
Set “1”
E1h.1
【
Clear FFC(Offset) RAM
】
Initial Data: Write Only
To clear the FFC Offset in data on the RAM.
Set “1”
E1h.3
【
Load FFC(Factory setting
)】
Initial Data: Write Only
To load the FFC Gain(Factory setting).
Set “1”
E1h.4
【
Set FFC
】
Initial Data: Write Only
To set the FFC value when FFC Manual mode was selected(81h).
Set “1”
E1h.6
【
Save FFC
】
Initial Data: Write Only
To save the FFC Gain value into the RAM.
Set “1”
E1h.7
【
Load FFC
】
Initial Data: Write Only
To load the FFC Gain from RAM.
Set “1”
E2h.0
【
Save Camera Setting
】
Initial Data: Write Only
To save the camera setting data into the RAM.
Set “1”
E2h.1
【
Load Camera Setting
】
Initial Data: Write Only
To load the camera setting data from RAM.
Set “1”
E2h.3
【
Load Camera Setting
(
Factory Default
)】
Initial Data: Write Only
To load the factory default setting from RAM.
Set “1”
EEh
【
Output Mode
】
Initial Data: It depends on camera model
To set the camera output mode.
Therefore it could be selectable of Camera link Full/Medium/Base configuration, Camera Link output CLK.
Selectable Output Mode is different for each model.
As for the detail, please see
FS-B2KU7CLU
,
FS-B4KU35CLU,FS-B4K7CLU
,
FS-B8KU35CLU,FS-B8KU7CLU
,
FS-B16KU35CLU
,
Minimum line period
*8bit (Fix)/10bit output can be selected through Output Mode.
*Maximum Frame rate on Internal Sync can be selected through Output Mode.
*FFC would be changed automatically through Output Mode when FFC Corrected Value Store Mode is Standard.
Product Specifications
43
Ver 1.12