Monochrome Field Update Line Scan Camera Link Series
Command No.
Bit No.
Command Description
81h
【
FFC Mode
】
Initial Data:1
To set the FFC mode.
*The camera will start the operation when changing the mode under Auto setting.
0:OFF
=>
Non-correction video output
1:ON
(
Gain + Offset
)
=>
Corrected video output
(
Gain + Offset
)
2:FFC value
=>
FFC value output on the video signal
3:Manual
(
by pixel
)
=>
Set the correction value into each pixel
4:Manual
(
all pixels
)
=>
Set the correction value into the all pixels
5:Auto
(
Gain
)
=>
Calculate the correct Gain value automatically
6:Auto
(
Offset
)
=>
Calculate the correct Offset value
automatically.
7:ON
(
only Offset
)
=>
Corrected video output
(
only Offset
)
82h
【
Select FFC (Gain,Offset)
】
Initial Data:1
To select Gain or Offset correction value on the Manual Mode of FFC Mode(81h).
0:Non
1:Gain
2:Offset
83h
【
FFC Corrected Value Output
】
Initial Data:0
To select FFC corrected value on the FFC value of FFC Mode(81h).
0:Upper bit
1:Lower bit
84-85h
【
FFC Data
】
Initial Data:0
To set the corrected vale on the Manual Mode of FFC Mode(81h).
0
~
65535
86-87h
【
FFC Address
】
Initial Data:0
To set the pixel address data on the Manual Mode of FFC Mode(81h).
0
~
Maximum value
(
It depends on camera model
)
*Left side of image is as “0”
88h
【
Target FFC Gain
】
Initial Data:200
To set the target level(8bit) on Auto (Gain) mode of FFC Mode(81h).
0
~
255
8Ah
【
Target FFC Offset
】
Initial Data:3
To set the target level(8bit) on Auto (Offset) mode of FFC Mode(81h).
0
~
255
8Ch
【
FFC Corrected Value Store Mode
】
Initial Data:0
To set the saving mode of FCC corrected value.
0: User Default Access Area =>
Use the one corrected FFC value (Automatically changed for output mode)
1: User BANK Area =>
Select the several corrected FFC value
*Under the Standard setting, corrected FFC value will be loaded automatically, if signal wave is changed for each output mode.
As for the detail, please refer to the
FFC Corrected Value Store Mode
.
Product Specifications
41
Ver 1.12