Monochrome Field Update Line Scan Camera Link Series
Command No.
Bit No.
Command Description
12h.0
【
Video Out
】
Initial Data:0
To set the camera output bit.
0:8bit
1:10bit
*Configurable output bit are depends on output mode. Some modes are 8bit only.
20-21h
【
Exposure Time
】
Initial Data:0
To set the camera exposure time.
0
~
65535
*When sync control is Internal, Exposure Time becomes a Line period, so you can change the Line period of camera by the
setting value of this parameter.
31h
【
Digital Gain
】
Initial Data:0
To set the Digital Gain.(This process works after received the data from sensor).
0
~
255
Digital gain formula is the following.
Gained Value =(1 +
Digital Gain
/64)*( Brightness Level -
FFC Offset Target
) +
FFC Offset Target
*This formula is based on FFC. This value is clamped by FFC Offset Target.
34h.0
【
Analog Gain
】
Initial Data:0
To set the Analog Gain.( This process works on the CMOS’s sensor registry).
0:OFF
1:ON
(
x 4
)
After this parameter has been set, the FFC should be reset for CMOS output due to the character being changed.
78h
【
Test Pattern
】
Initial Data:0
To set the Test pattern output.
0:OFF
1:Sawtooth wave
2:Triangle wave
3:Gray Scale 128 Steps
4:Moving Sawtooth wave
Product Specifications
40