background image

6300-Series Remote Display

 

 

 

SenSource, Inc.

 • Youngstown, OH U.S.A. 

www.sensourceinc.com • 800.239.1226

 

 

12   

Rev. 5/24/2013

 

 

 

T

I M E R  

D

I S P L A Y  

F

O R M A T

 

 

This may be changed freely without disrupting the running time (unless the displayed count rolls over). 

As Time 

Press [MENU] "230" [ENTER]. 

As Interval 

Press [MENU] "231" [ENTER]. 
Press [MENU] "24x" [ENTER], where 'x' is the interval unit selected. 
Note: In countdown mode, fractional time is rounded up to the next interval unit, i.e., 1.5 minutes shows as 2 minutes.

 

 

T

I M E R  

O

P T I O N S

 

 

The following options apply to this mode. See "Programming De

fi

nitions" for more information. 

 

1.3. Reload Time/Interval 
1.4. Chime 1 Time/Interval 
1.5. Chime 2 Time/Interval 
2.3. Display Format 
• 2.3.0. As time 
• 2.3.1. As Specified Interval 
2.4. Interval Unit 
3.1. Internal Chime 
3.2. External Chime 
3.3. Chime Volume 
4.1. Smallest Time Unit Displayed (STU) 
4.2. Largest Time Unit Displayed (LTU) 
4.3. Leading Zero Suppression 
4.4. Colon Flash Rate 
5.1. On Rollover 
5.2. On Zero 
5.3. Chime on Zero 
6.1. Input 1 Action 
6.2. Input 2 Action 
6.3. Pushbutton/volt 
6.4. N.O./N.C. 
6.5. Button Logic 
6.6. Button Debounce 
6.7. Remote Lockout

 

 

T

I M E R  

S

L A V E  

D

I S P L A Y  

O

P T I O N S

 

 

See the "Slave Displays" section for more information about multiple- displays. 
 

Set slave mode: [MENU] "213" [ENTER]. 
Set display format 
As time: [MENU] "230" [ENTER]. 
As interval: [MENU] "231" [ENTER]. 
Set interval unit displayed 
Press [MENU] "24x" [ENTER], where 'x' is the interval unit selected. 
Set time units displayed 
STU seconds: [MENU] "411" [ENTER]. 
LTU hours: [MENU] "423" [ENTER].

 

Summary of Contents for 6300 Series

Page 1: ...6300 Series Remote Display SenSource Inc Youngstown OH U S A www sensourceinc com 800 239 1226 Rev 5 24 2013 1 ...

Page 2: ...ay Settings 9 Clock 10 Clock Display 10 Clock Date Time 10 Clock Options 10 Clock Slave Display Options 10 Count Up Down Timer 11 Timer Setting the Display 11 Timer Operation 11 Timer Display Format 12 Timer Options 12 Timer Slave Display Options 12 Counter Detailed Instructions 13 Counter Setting Display 13 Counter Operation 13 Counter Options 13 Counter Slave Display Options 13 TAKT Time Detaile...

Page 3: ...mable Options 17 Options Programmable 17 Options Table Summary 18 Options Table Summary continued 19 Options Definitions 20 Options Setup 20 Options Definitions continued 22 Options Behavior 22 Options Chime 23 Options Display 23 Options Events 23 Options Definitions continued 24 Options Inputs 24 Trouble Shooting 27 Mounting Template 28 LIMITED WARRANTY 29 ...

Page 4: ... are available in four styles 2 3 4 and 6 digit displays available FEATURES 2 digit 6320 3 digit 6330 4 digit 6340 and 6 digit 6360 display options Intelligent LED display Line powered with battery backup 2 inputs Built in audio chime Remote controlled COMPONENTS Systems are custom built these are components of a standard build power supply LCD display Remote 100 wire GETTING STARTED Read the inst...

Page 5: ...6300 Series Remote Display SenSource Inc Youngstown OH U S A www sensourceinc com 800 239 1226 Rev 5 24 2013 5 HARDWARE OVERVIEW 6300 SERIES HARDWARE ...

Page 6: ...6300 Series Remote Display SenSource Inc Youngstown OH U S A www sensourceinc com 800 239 1226 6 Rev 5 24 2013 SPECIFICATIONS ...

Page 7: ...6300 Series Remote Display SenSource Inc Youngstown OH U S A www sensourceinc com 800 239 1226 Rev 5 24 2013 7 INSTALLATION ...

Page 8: ...6300 Series Remote Display SenSource Inc Youngstown OH U S A www sensourceinc com 800 239 1226 8 Rev 5 24 2013 REMOTE CONTROL REMOTE PUSH BUTTON DEFAULT SETTINGS ...

Page 9: ...6300 Series Remote Display SenSource Inc Youngstown OH U S A www sensourceinc com 800 239 1226 Rev 5 24 2013 9 QUICK START DISPLAY SETTINGS ...

Page 10: ...te in the format MM DD YY then press ENTER CLOCK OPTIONS The following options apply to this mode See Programming Definitions for more information 1 1 Current Time 1 2 Current Date 1 4 Chime Time 1 1 5 Chime Time 2 2 2 Clock Format 2 3 Display Format 2 3 0 As time 2 3 2 As date 3 1 Internal Chime 3 2 External Chime 3 3 Chime Volume 4 1 Smallest Time Unit Displayed STU 4 2 Largest Time Unit Display...

Page 11: ...ons Count Up Mode Input 1 Start stop count up Input 2 Zero count Countdown Mode Input 1 Start stop countdown Input 2 Reload default time Setting the Time Remote Control Type in the new time and press ENTER If the display is running it will continue to count up or down Setting the Reload Time Remote Control Press MENU 13 ENTER Type in the desired time and press ENTER Setting the Chime Times Remote ...

Page 12: ...l 1 5 Chime 2 Time Interval 2 3 Display Format 2 3 0 As time 2 3 1 As Specified Interval 2 4 Interval Unit 3 1 Internal Chime 3 2 External Chime 3 3 Chime Volume 4 1 Smallest Time Unit Displayed STU 4 2 Largest Time Unit Displayed LTU 4 3 Leading Zero Suppression 4 4 Colon Flash Rate 5 1 On Rollover 5 2 On Zero 5 3 Chime on Zero 6 1 Input 1 Action 6 2 Input 2 Action 6 3 Pushbutton volt 6 4 N O N C...

Page 13: ... def initions Input 1 Increment count by one Input 2 Decrement count by one Setting a new count Remote Control Type in the new number and press ENTER Fast Inputs For events faster than 10 items per second use option 6 6 1 COUNTER OPTIONS The following options apply to this mode See Programming Definitions for more information 2 3 Display Format 2 3 3 As count 6 1 Input 1 Action 6 2 Input 2 Action ...

Page 14: ...A Clear Reset internal timer and zero TAKT count Pushbuttons To change the default function of the push buttons see options 6 1 and 6 2 in the Options Definitions Input 1 Start stop TAKT timer Input 2 Reset internal timer and zero TAKT count Setting a New TAKT Count Remote Control Type in the new value and press ENTER If the display is running it will continue to increment Changing the TAKT Interv...

Page 15: ...eferred to as slave displays All of the operating modes for the 6300 Series support slave displays Slave displays get their information from the master via 485 communications Terminals A B COMM Connect slave displays to the master with 3 or 5 conductor wire The 5 conductor wire allows three wires for communications and two wires for power to slave displays Five conductor wire is suitable for short...

Page 16: ...rogramming Definitions for more information 2 3 Display Format 2 3 0 As time 2 3 1 As specified interval 2 3 2 As date 2 3 3 As count for unit counter and TAKT timer modes 2 4 Interval Unit if 2 3 1 set 3 1 Internal Chime 3 2 External Chime 3 3 Chime Volume 4 1 Smallest Time Unit Displayed STU for 2 3 0 or 2 3 1 4 2 Largest Time Unit Displayed LTU for 2 3 0 or 2 3 1 4 3 Leading Zero Suppression 4 ...

Page 17: ...umber i e Menu 12 to change the date Then press Enter Next type in up to six digits of the value representing the time or date followed by enter i e if setting time to 3 00 type 300 Enter Section 1 6 is a special Quick Set section It is actually not a memory area at all but a function that sets all other memory areas to a factory default condition For instance if you want to set all memory areas t...

Page 18: ...6300 Series Remote Display SenSource Inc Youngstown OH U S A www sensourceinc com 800 239 1226 18 Rev 5 24 2013 OPTIONS TABLE SUMMARY Options in bold are the default settings ...

Page 19: ...6300 Series Remote Display SenSource Inc Youngstown OH U S A www sensourceinc com 800 239 1226 Rev 5 24 2013 19 OPTIONS TABLE SUMMARY CONTINUED ...

Page 20: ...tdown timer s reload time or interval Any time the countdown timer is reset it will go back to this value Prompt Time format 2 3 0 HH MM SS ENTER DDDD ENTER Interval format 2 3 1 NNNNNN ENTER HH hours MM minutes SS seconds DDDD days N quantity of the set interval unit This option also serves as the TAKT time interval Prompt TAKT time 2 1 5 HH MM SS ENTER DDDD ENTER HH hours MM minutes SS seconds D...

Page 21: ...ement at midnight automatically 1 6 3 Countdown Time to New Year s Day Counts down the time until New Year s Day First set the date and time Important Do not use daylight savings when setting the time or the count will be off by 1 hour Next select this option The display will begin counting down the time remaining until the New Year in the format DDDD HH MM SS Note that slave displays can be used ...

Page 22: ...to show time in standard 12 hour format or in 24 hour military time 2 3 Display Format Determines how the unit displays information to the user This may be changed freely without disrupting the running time see caution below about interval units Display formats do not apply to all modes 2 3 0 As time Show in standard time format DDDD HH MM SS hh Max 9999 23 59 59 99 Applies to 2 1 0 2 1 1 2 1 2 2 ...

Page 23: ...triac option is recommended For DC loads the relay option is recommended 3 3 Chime Volume Internal Chime Sets the volume of the internal chime OPTIONS DISPLAY 4 1 STU Range Lock Sets the smallest time unit that will be shown by the display i e To have a 4 digit display show hours and minutes never seconds set this value to 2 4 2 LTU Range Lock Sets the largest time unit that will be shown by the d...

Page 24: ...wn 5 2 3 Count Up Start counting up from zero 5 2 4 Flash Zero Flashes zero until a button is pressed 5 3 Chime on Zero Determines if the chime should sound when the count down time interval 2 1 2 reaches zero 5 3 0 Off Does not chime 5 3 1 Momentary Momentarily activates the internal and external chimes 5 3 2 Continuous Activates internal and external chimes Continues to sound the internal chime ...

Page 25: ... stops timer 6 2 4 Reset Resets timer 6 2 5 Stop Reset Stops Timer and Resets it 6 2 6 Reset Start Resets Timer and Starts it 6 2 7 Start Stop Reset Alternate starts and stops timer resetting each time 6 3 Pushbutton Voltage Sets whether the display should source 5V to monitor buttons or it should accept 5V TTL level from an external input 6 3 0 Push buttons Buttons at input no external voltage ap...

Page 26: ...bounce many times This results in additional button presses that the user did not intend This option ignores the additional button bouncing 6 6 0 None No debouncing Provides an instant response to any input Not recommended for push buttons 6 6 1 Fast triggers on the leading edge of input has a small delay between inputs This is useful where the input is a high speed low noise signal some microswit...

Page 27: ...6300 Series Remote Display SenSource Inc Youngstown OH U S A www sensourceinc com 800 239 1226 Rev 5 24 2013 27 TROUBLE SHOOTING ...

Page 28: ...6300 Series Remote Display SenSource Inc Youngstown OH U S A www sensourceinc com 800 239 1226 28 Rev 5 24 2013 MOUNTING TEMPLATE ...

Page 29: ...OES NOT OPERATE AS WARRANTED ABOVE CUSTOMER S SOLE REMEDY FOR BREACH OF THAT WARRANTY SHALL BE REPLACEMENT OR REPAIR OF THE PRODUCT OR PART OR REFUND OF THE PURCHASE PRICE PAID AT SENSOURCE INC S OPTION TO THE FULL EXTENT ALLOWED BY LAW THE FOREGOING WARRANTIES AND REMEDIES ARE EXCLUSIVE AND ARE IN LIEU OF ALL OTHER WARRANTIES TERMS OR CONDITIONS EXPRESS OR IMPLIED EITHER IN FACT OR BY OPERATION O...

Reviews: