Case #2
The scan was conducted at a test pad outdoors (Figure 7-2a & Figure 7-2b). The grid size was
1200x1200mm, normal resolution.
The main feature of this grid scan is the overlapping wire mesh, seen prominently at adjacent
depths. The reason that it shows at 2 different depths is that the mesh dips in certain areas, a
result of the weight of the concrete as it was being poured. From the pictures, it can be seen that
the mesh has a spacing of 200mm.
a)
b)
Figure 7-2: