![Sensor Therm Polaris PI16 User Manual Download Page 15](http://html1.mh-extra.com/html/sensor-therm/polaris-pi16/polaris-pi16_user-manual_1244044015.webp)
Infrared Temperature Switch (Hot Metal Detector) Polaris PS09 / PI16
Technical Data
15
6
Technical Data
Model
PS09
PI16
Temperature ranges
550
–1400°C
650
–1800°C
250
–1000°C
300
–1300°C
350
–1800°C
Spectral range
0.7
–1.1 µm
1.45
–1.8 µm
Switch temperatures
Can be set within the limits of the temperature range
Signal processing
Digital
Measurement uncertainty
± 1% of adjusted switching point temperature (T
A
=23°C,
ε=1, t
90
=1 s)
Repeatability
0.5% of adjusted switching point temperature (T
A
=23°C,
ε=1, t
90
=1 s)
Response time t
90
4 ms, adjustable to 10 s
Emissivity
ε
20
–100%
Power supply
24 V DC (possible range 12
– 30 V DC)
Power consumption
Max. 0.5 VA (without switching output current)
Switching outputs
2 transistor outputs, switches the positive supply voltage to the output
(positive switching), max. current 30 mA
Digital interface
RS232 or RS485, addressable, baud rate 1.2
–57.6 kBd,
galvanically isolated
Parameters
changeable and readable via serial interface:
switching temperature, emissivity, response time, device temperature,
address, baud rate
Sighting
Laser targeting light (laser class 2, max. output power 1 mW, 635 nm)
Operation indicator
Green LED
Switching indicator
2 yellow LEDs
Weight
300 g
Protection class
IP65 (according to DIN 40 050) with mounted connection cables
Ambient temperature
0
–70°C
Storage temperature
-20
–70°C
Rel. humidity
No condensing conditions
CE label
According to EU directives for electromagnetic immunity
6.1
Storage
Store packages under the following conditions:
Do not store outdoors
Store dry and dust-free
Do not exposed to corrosive media
Protect from direct sunlight
Avoid mechanical vibrations
Storage temperature: -20 to 85°C
Relative humidity: max. 95%,
no condensing conditions
6.2
Dimensions
Dimensions in mm