Vision Viewer CE FA 45 GB - 068-14298 - 23.03.2010-00
Mounting and
operating instructions
23
Sensor correctly connected?
- Power supply 24V DC
- Networkcable (crossed) Nr. 902-51736
Electrical connection OK?
- green Pwr LED at FA 45 active?
- Status LED at networkadapter active?
- and/or LAN Status shows "Connection
established". (Control panel
Ö
Network-
connections
Ö
LAN-Connection
Ö
Status)
Connect Sensor correctly!
- Power supply 24V DC
- Networkcable (crossed) Nr. 902-51736
no
yes
no
SensoFinder finds Sensor?
- start SensoFinder
- press button "Find"
- mark Sensor
- Button "Connect" is aktive?
"Repair" Networkconnection
Please contact your system administrator as this can cause
problems!
Start
Ö
Control panel
Ö
Networkconnections
Ö
Right mouse click
on used "LAN connection"
Ö
Repair
(delets ARP Cache, amongst others).
IP-Connection test
- in Command Line
:
ping 192.168.100.100
(IP address of the sensor) [ENTER] .
If four positive answers are displayed, go on with "Yes"- path
(Command input:
Start
Ö
All Programs
Ö
Accessories
Ö
Command Line)
SensoFinder starts applicaiton- software?
- Double click on sensor in the list
- PC / application- software starts
Sensor- and Softwareversion test
Sensorversion is displayed in the SensoFinder (e.g. 40). Table of
compatibility and corresponding software at www.sensopart.com
no
Now the parameter setting of the sensor /
application can be done
yes
yes
yes
yes
IP address of PC fits to IP of Sensor?
Sensor IP: 192.168.100.100/24 (default)
- PC: e.g. 192.168.100.101/24
( /24 means, 24Bit Subnetmask =
255.255.255.0)
yes
Deacticate / adapt firewall
Please contact your sytem administrator
IP-Connection test
(see above)
Caution!
After parameter setting is finished, reactivate firewall again!
no
no
no
Important:
To configure the PC via
Direct Connection
it is neccessary to change it´s IP- configuration.
Please contact your system administrator to inform about changes !
Control / correct settings
- IP of PC (fix, to the sensor corresponing IP):
e.g. 192.168.100.101; - Subnetmask: 255.255.255.0
Configuration: Start
Ö
Control panel
Ö
Networkconnections
Ö
LAN-Connection
Ö
Properties
Ö
Internetprotocol (TCP/IP)
yes
yes
no
yes
yes
Procedure/Trouble-shooting – Direction connection
Establishing an operational Ethernet connection between FA 45 Vision Sensor and Vision Viewer CE
Fig. 8
155-00509