FA 46 Vision Sensor GB - 068-14297 - 10.02.2011-05
Mounting and
operating instructions
75
6
Communication via Ethernet or RS422
6.1
Data formats of commands and data output
Transmission protocol
Data transmission via RS422 is carried out with the following basic parameters:
Baud rate
between 9600 and 115200 baud depending on setting
Data bits
8
Parity
none
Stop bit
1
6.2
ASCII transmission
6.2.1
Commands to sensor in ASCII
Trigger (ASCII) Request string to Sensor
Byte no.
ASCII contents
Significance
1
T
Trigger
2
R
3
G
Trigger (ASCII) Response string from sensor
Byte no.
Contents
Significance
1
T
Trigger
2
R
3
G
4
P
F
Pass
Fail
Additional information
Accepted in run mode:
Yes
Accepted in configuration mode:
Yes
Accepted when Ready Low:
No
Status of Ready signal during processing:
Low