RailPilot system manual
10
2 Setting FR 85 with PC software
2.1 Serial communication FR 85-2 ILLG-S1L5
FR 85-2 ILLG – S1L5 only communicates with the vehicle control system via the RS485 interface.
When installing with a suitable vehicle control system (currently DETO and LJU), it is merely necessary to
set the correct baudrate.
The
factory setting
is
57.6 kBaud
.
This setting makes the FR 85-2 ILLG – S1L5 sensor suitable for immediate use with the DETO control
system. When used with the
LJU control system
, the baudrate must be set to
62.5 kBaud
(see transmission protocol data sheet and description of test software).
Test of
FR 85-2 ILLG – S1L5
on a PC with FR85ILL_tester.exe software
RailPilot FR 85-2 ILLG – S1L5 can be connected to a PC for test and adjustment purposes via a RS485 –
RS232 interface converter den.
The sensor is available with preset baudrate:
Type / order reference
Baudrate
Suitable for control system Part no.
FR 85-2 ILLG-S1L5
62.5 kB
LJU
529-11014
FR 85-2 ILLG-S1L5
57.6 kB
DETO
529-11008