- 14 -
3.2
Manual tare
The unit allows a tare value to be defined manually (*). To do this, press the FUN and T
keys at the same time without leaving weight mode. The unit will enter manual tare edit
mode, with the rightmost digit flashing to indicate the tare at this moment. To change the
tare value displayed, use the T key to increase the flashing digit value, the B key to change
digit, the FUN key to cancel and leave without validating, and the ENTER key to validate the
tare value entered, taring the unit whilst locking the Tare.
When a manual tare is active, printing the tare on a ticket will be accompanied by the
symbol "*", indicating that weighing was carried out with a manual tare.
(*) The manual tare function is NOT available if the limit, traffic light or any
dose option is enabled (options available through the APPLIC programming
submenu).
========================================
N.WEIGH. CODE TARE kg NET kg
========================================
1 100350 * 21.57 0.216
T
The tare lock function is only available if initial zero option (INIT.Z) has
been enabled in the WE.CTR programming submenu.
Summary of Contents for SC-A1
Page 2: ...2...