Preparazione dell’ambiente   

  3 

Preparing the environment 

moduli 

XPORT 

dell

’I/F 

TCPIP, 

sono 

stati 

pre

programmati  per  funzionare  in  DHCP,  ovvero  il  loro 

indirizzo  IP  lo  otterranno  automaticamente  dal  master 
della rete. Questo affinché in prima battuta sulla rete non 
siano generati potenziali conflitti di doppi indirizzamenti. 
 
A questo punto occorre installare sul P.C. due programmi 
che  comunicheranno  con  le  centrali,  scaricabili  dal  sito 
LANTRONIX. 
 
“Device Installer” 

https://www.lantronix.com/products/deviceinstaller/

 

 
“CPR” 

https://www.lantronix.com/products/com-port-

redirector/

 

 

 

The  modules  XPORT  of  the  I/F  TCPIP,  have  been  pre-
programmed to operate in DHCP, so, their IP address will 
automatically  get  from  the  network  master.  This  for  not 
generating potential conflicts of double addressing on the 
network. 
 
You  must  now  install  on  your  P.C.  two  programs,  from 
LANTRONIX  website,  to  communicate  with  the  control 
unit. 
 
“Device Installer” 

https://www.lantronix.com/products/deviceinstaller/

 

 
“CPR” 

https://www.lantronix.com/products/com-port-

redirector/

 

 

 

Impostazione del Modulo 

  4 

Settings 

La  prima  volta  che  si  lancia  il  programma  potrebbe 
comparire un messaggio in cui non si riconosce nessuna 
rete.  
In questo caso occorre selezionare sotto il menu “Tools” 
la  voce  “Options”  e  selezionare  “Connessione  alla  rete 
locale  (LAN)”,  cliccare  “Apply”  e  dopo  “OK”  per  ritornare 
nella schermata principale. 
 

1. 

Nella  schermata  principale  cliccare  su  “Search” 
per cercare il modulo/i. 

 
2.  Dopo  qualche  secondo  nella  finestra  di  sinistra 

dovrebbe  comparire  il  nome  del  modulo  “xPort

 

con 

il 

suo 

indirizzo 

IP 

(assegnato 

automaticamente  dalla  rete  in  DHCP)  il  suo 
Hardware

Address Univoco (MAC

Address), e lo 

status che dovrebbe essere Online. 

 

Il fine ultimo è quello di assegnare un Virtual Com Port sul 
P.C. che comunicherà con la centrale che farà riferimento 
all’indirizzo  IP  del  modulo  XPORT.  Per  far  ciò  occorre 
cambiare 

l’indirizzo  IP  del  modulo  in  un  indirizzo  IP 

Statico,  i.  In  questo  modo  spegnendo  e  riaccendendo  il 
sistema l’indirizzo IP del modulo sarà sempre lo stesso e 
la Virtual Com Port assegnata sul P.C. (che fa riferimento 
all’indirizzo IP del modulo) funzionerà senza problemi. 

 
3.  Selezionare  nella  voce  di  sinistra  il  modulo,  e 

nella barra dei comandi cliccare su “ASSIGN IP”. 

 
4.  Si apre una finestra in cui occorre selezionare la 

voce  “Assign  a  specific  IP  address”,  premere  il 
pulsante “Next”. 

 
5.  Compare  il  settaggio  attuale  del  modulo  definito 

su  tre  voci  modificabili:  “IP  address”,  “Subnet 
mask” e Default gateway. Modificare le voci che 
interessano  in  base  all’impostazione  della  rete 
ETHERNET  e  cliccare  Next,  e  nella  finestra 
successiva  pigiare  il  pulsante  “Assign”.  Dopo 
qualche  secondo  di  attesa  in  cui  le  nuove 
impostazioni  e  il  comando  di  riavvio  sono  inviati 
al modulo, 

 

 

 

The  first  time  you  launch  the  program  the  network  could 
not recognized the LAN. 
 
In this case, you must select under the "Tools" menu  the 
item  "Options"  and  select  "Local  Area  Network  (LAN)", 
click "Apply" and then "OK" to return to the main screen. 
 
 

1.  On  the  main  screen  click  "Search"  to  find  the 

module/s. 

 

2.  After  a  few  seconds  on  the  left  window  you 

should  see  the  name  of  the  module 

"xPort” with 

its  IP  address  (automatically  assigned  by  the 
DHCP  network),  its  Unique  Hardware-Address 
(MAC  Address)  and  the  status  that  should  be 
Online. 

 
The  ultimate  goal  is  to  assign  a  Virtual  Com  Port  to  the 
P.C.  that  will  communicate  with  the  control  panel.  This 
control  panel  will  refer  to  the  IP  address  of  the  module 
XPORT.  To do this we need to change the IP address of 
the module into a static IP address, i. In this way, turning 
off and on the system's  the IP address of the module  will 
be always the same and the Virtual Com Port assigned to 
the P.C. (Which refers to the module's IP) will work fine. 
 

3.  Select  the  module  on  the  left  item,  and  click 

"ASSIGN 

IP” on the command bar". 

 

4.  It  opens  a  window  where  you  must  select  " 

Assign  a  specific  IP  address

”  than  press  the 

button "Next". 

 

5.  You  will  see  the  current  setting  of  the  module 

defined  in  three  editable  voices:  "IP  address", 
"Subnet Mask", and Default gateway. Change the 
setting  of  the  Ethernet  network  and  click 

“Next”. 

Than,  press  the  "Assign"  button.  After  a  few 
seconds, in which the new setting and the restart 
command are sent to the module, 

 

 
 
 

Summary of Contents for I/F TCPIP

Page 1: ...o delle centrali tramite l utilizzo della connessione RJ45 per il controllo locale tramite rete LAN I F TCPIP Module for interfacing the control unit through the RJ45 connection for local control via...

Page 2: ...NDEX 1 INTRODUZIONE 3 1 INTRODUCTION 3 1 1 Descrizione 3 1 1 Description 3 2 Montaggio del Modulo 3 2 Module mounting 3 3 Preparazione dell ambiente 5 3 Preparing the environment 5 4 Impostazione del...

Page 3: ...ERNET RS232 sul connettore P2 RS232 della CENTRALE MULTISCAN situato sul pannello posteriore e identificabile con la dicitura SERIAL PORT 4 Bloccare l interfaccia ETERNET RS232 con le 3 viti 3MAx6 in...

Page 4: ...el pannello posteriore 5 Riagganciare il pannello posteriore al RACK di alluminio riavvitando le 10 viti 6 Riaccendere la Centrale e collegare il cavo ETHERNET all interfaccia ETHERNET RS232 If you ne...

Page 5: ...spegnendo e riaccendendo il sistema l indirizzo IP del modulo sar sempre lo stesso e la Virtual Com Port assegnata sul P C che fa riferimento all indirizzo IP del modulo funzioner senza problemi 3 Sel...

Page 6: ...necessario solo la voce BAUD RATE e premere OK b Nel menu a sinistra cliccare Apply Settings e attendere il completamento dell operazione Per controllare l effettiva modifica del parametro occorre ri...

Page 7: ...nare il protocollo di comunicazione Modbus TCP necessario andare nella sezione Channel1 Connection e dal menu a tendina Protocol selezionare la voce Modbus To select the Modbus TCP communication proto...

Page 8: ...dirizzo IP 2 In the Device List at the bottom of the window you should see the form preceded by its IP address 3 Cliccare sul comando Add Remove si aprir una finestra con l elenco di tutte le Com Port...

Page 9: ...s sar riscritta con tutte le informazioni in nero Chiudere il programma CPR 9 Nel pannello di controllo di Windows sotto Sistema Gestione dispositivi e Porte COM e LPT si potr vedere la nuova linea se...

Reviews: