background image

13

 

Adjusting the AF level

Monitoring facility

Two infra-red transmission diodes 

 

 are located behind the display window

on the modulator front panel. They transmit the complete infra-red signal for
monitoring purposes. Thus you can check the selected transmission channel
with a suitable receiver (e.g. an HDI 1029 PLL). The transmission distance
of the IR transmitter diodes is approx. 1.2 m.

By

 simultaneously 

pressing the buttons "

AF LEVEL

and

 "

+

" or "

-

" you can

adjust the AF level for the transmission channel you have just selected.

With the "

+

" button you increase the AF level.

With the "

-

" button you decrease the AF level.

The level is adjusted correctly when the modulation indicator 

 occasio-

nally reaches the red part of the display (full modulation).

When both buttons are released, the selected AF level is stored.

This completes all settings for the first audio input channel. For adjusting the
next input channel, start again with 

CHOOSING THE AUDIO INPUT

.

Channel display

All transmission channels used are displayed: When a given input delivers
its signal to an IR transmission channel, the corresponding LED 

 lights up.

Summary of Contents for SI 29-5

Page 1: ...8 SI 29 5 Instructions for use...

Page 2: ...tor can be used with the respective voltage of your country NT 29 EU 230 V 50 60 Hz Cat no 04002 NT 29 120 120 V 50 60 Hz Cat no 04003 NT 29 UK 240 V 50 60 Hz Cat no 04004 AF inputs Five XLR input soc...

Page 3: ...ms cascadable SZI 1029 High power infra red radiator IR radiating power 5 W socket for connection of additional SZI 1029 SZI 1029 10 or SZI 20 Black or unpainted aluminium housing SZI 1029 10 High pow...

Page 4: ...ximum number of transmisson channels 1 5 2 10 3 15 4 20 5 25 6 30 7 32 N B Do not duplicate channel numbers Cascade the infra red modulators with a BNC connection cable Use the cascading sockets for i...

Page 5: ...for the selected input Choosing the IR transmission channel Switching a channel off By simultaneously pressing the buttons CHANNEL and or you start the search for the infra red transmission channel wh...

Page 6: ...djust the AF level for the transmission channel you have just selected With the button you increase the AF level With the button you decrease the AF level The level is adjusted correctly when the modu...

Page 7: ...isplay Channel 14 655 kHz Display Channel 30 1295 kHz Display Channel 15 695 kHz Display S Channel 31 1335 kHz Display Nominal peak deviation 6 kHz 7 kHz Amplitude limitation limiting amplifier max 30...

Page 8: ...Sennheiser electronic GmbH Co KG D 30900 Wedemark Telefon 05130 600 0 Telefax 05130 600 300 Printed in Germany Publ 6 97 54598 A03...