MKH 416
|
3
Specifications
Polar diagram
Frequency response curve
The original measurement protocol is included with each microphone,
measured from 50 to 20,000 Hz.
Frequency response
40 ... 20,000 Hz
Transducer principle
RF condenser microphone
Pick-up pattern
super-cardioid/lobar
Sensitivity (free field, no load)
(1 kHz)
25 mV/Pa ±1 dB
Nominal impedance
25
Ω
Min. terminating impedance
approx. 800
Ω
Equivalent noise level
CCIR-weighted (CCIR468-3)
A-weighted
approx. 24 dB
approx. 13 dB
Max. sound pressure level
130 dB SPL
Power supply
48 V ± 4 V phantom powering
Current consumption
approx. 2 mA
Temperature range
–10 °C to +70 °C
Finish
matt black
Connector
3-pin XLR connector
Pin assignment
1: Ground, housing; supply (–)
2: AF (+); supply (+)
3: AF (–); supply (–)
according to IEC publication
268-14/2
Dimensions
∅
19 x 250 mm
Weight
175 g
30°
30°
0°
0
5
10
15
20
25
dB
60°
60°
90°
90°
120°
120°
125 Hz
250 Hz
500 Hz
1000 Hz
2000 Hz
4000 Hz
8000 Hz
16000 Hz
150°
150°
180°
1.00
dB V
-20
-30
-40
-50
-60
-70
50 Hz
100
100 Hz
200 Hz
500 Hz
1 kHz
2 kHz
5 kHz
10 kHz
20 kHz
Linear
„Low Cut“