47
Specifications
Overall device
Current consumption
max. 0.4 A
Power consumption
with receiver switched on: max. 20 W (50 VA)
with receiver switched off, booster supply voltage switched on: max. 9.5 W
with receiver and booster supply voltage switched off: max. 4 W
Mains connector
3-pin, protection class I, as per IEC/EN 60320-1
Dimensions W x D x H [mm]
436 x 215 x 44 (without rack mount “ears”)
Weight
approx. 4080 g (incl. rack mount “ears”)
approx. 3600 g (without rack mount “ears”)
Booster supply
12 V DC via antenna socket
max. 200 mA each, short-circuit proof, switchable
Ethernet
IEEE 802.3-2002, shielded RJ 45 socket with optional locking facility
Digital output
AES3-2003, XLR-3, 44.1, 48, 88.2 or 96 kHz SR, 24 bits,
externally synchronizable
Word clock connection
2 BNC sockets (75
Ω
), daisy chain output
Accepted sampling rates
44.1 kHz, 48 kHz, 88.2 kHz, 96 kHz
Word clock input
75
Ω
, transformer balanced, AC-coupled
input voltage range 200 mV … 5 Vpp
max. input voltage 15 V (DC + AC)
Word clock output
75
Ω
, transformer balanced, AC-coupled
output voltage 2.5 V± 250 mV at 75
Ω
source impedance
Operating conditions
Ambient temperature
–10 °C to +55 °C
Relative humidity
max. 85 % at 40 °C (non condensing)
Power supply
100 to 240 V~, 50/60 Hz
Protection against dripping and
splashing
the product must not be exposed to dripping and splashing (IP 20)
Storage and transport
conditions
Ambient temperature
–25 °C to +70 °C
Relative humidity
max. 90 % at 40 °C
Protection against dripping and
splashing
the product must not be exposed to dripping and splashing (IP 20)
Shock test
shock test according to IEC 68 or EN 60068, T2-27
In compliance with
Europe
USA
EMC
EN 301489-1/-9
Radio EN 300422-1/-2
Safety
EN 60065
47 CFR 15
subpart B
Approved by
Industry Canada
RSS 123, IC: 2099A-EM 373x2